Back

Inactivation of Microorganisms in the Complex Regions of Transvaginal Ultrasound Probes By a UVC-LED Light Based Disinfection System

Yasir, M.; Willcox, M.

2026-03-27 microbiology
10.64898/2026.03.23.713795 bioRxiv
Show abstract

Endocavity ultrasound transducers, particularly transvaginal ultrasound (TVUS) probes, contain intricate structures such as notches, grooves, lens surfaces, and handle edges that are highly susceptible to microbial contamination yet difficult to disinfect using conventional high-level disinfection (HLD) methods. This study evaluated the efficacy of a novel ultraviolet-C light-emitting diode (UV-C LED) HLD system in eliminating microbial contamination from these complex probe surfaces. Two TVUS probes were sampled from predefined high-risk regions before and after disinfection following clinical use. Probe A was sampled at the top and bottom notches and both sides of the handle, while Probe B was assessed at the lens, edges, and bent groove regions. Microbial contamination was quantified using swab sampling, culture on agar plates, and identification via MALDI-TOF. Environmental sampling of examination and disinfection rooms was also performed. To assess this system robustness, probe sites were repeatedly inoculated with Bacillus subtilis spores and evaluated following UV-C treatment. Before UV-C treatment, contamination rates ranged from 25% to 57% across sampled regions, with microbial loads reaching up to 3.9 log CFU. Identified organisms included Staphylococcus epidermidis, Pseudomonas koreensis, Bacillus cereus, and Propionibacterium spp. Probe sheaths were also predominantly contaminated with Staphylococcus epidermidis., with counts reaching up to 4.3 log CFU, Environmental sampling revealed diverse microbiota, with higher contamination levels in examination rooms compared to disinfection areas. Following 90 seconds of UV-C exposure, no microbial growth was detected on any sampled site, indicating 100% decontamination. Additionally, UV-C treatment achieved >6.7 log reduction of B. subtilis spores across all tested regions. These findings demonstrate that UV-C LED technology provides rapid, effective, and consistent high-level disinfection of complex TVUS probe surfaces, supporting its potential as a rapid and reliable disinfection modality in clinical setting.

Matching journals

The top 10 journals account for 50% of the predicted probability mass.

1
PLOS ONE
4510 papers in training set
Top 8%
19.5%
2
Scientific Reports
3102 papers in training set
Top 5%
10.5%
3
Environmental Science & Technology
64 papers in training set
Top 0.8%
3.7%
4
Environmental Pollution
35 papers in training set
Top 0.8%
3.7%
5
Nature Communications
4913 papers in training set
Top 44%
2.7%
6
Biomedical Optics Express
84 papers in training set
Top 0.5%
2.5%
7
Journal of Visualized Experiments
30 papers in training set
Top 0.2%
2.2%
8
Journal of Hospital Infection
27 papers in training set
Top 0.2%
2.2%
9
Frontiers in Microbiology
375 papers in training set
Top 5%
1.7%
10
Applied and Environmental Microbiology
301 papers in training set
Top 2%
1.7%
50% of probability mass above
11
American Journal of Infection Control
12 papers in training set
Top 0.1%
1.5%
12
Infection Control & Hospital Epidemiology
17 papers in training set
Top 0.2%
1.5%
13
Viruses
318 papers in training set
Top 3%
1.5%
14
Advanced Science
249 papers in training set
Top 14%
1.3%
15
Frontiers in Cellular and Infection Microbiology
98 papers in training set
Top 4%
1.3%
16
npj Biofilms and Microbiomes
56 papers in training set
Top 1%
1.3%
17
mSphere
281 papers in training set
Top 4%
1.3%
18
Applied Sciences
24 papers in training set
Top 0.4%
1.3%
19
Science of The Total Environment
179 papers in training set
Top 4%
1.2%
20
Microbiology Resource Announcements
22 papers in training set
Top 0.6%
1.0%
21
ACS Sensors
45 papers in training set
Top 1%
0.9%
22
Microbiology Spectrum
435 papers in training set
Top 4%
0.9%
23
Indoor Air
10 papers in training set
Top 0.3%
0.9%
24
Journal of Infection
71 papers in training set
Top 2%
0.9%
25
Water Research
74 papers in training set
Top 1%
0.9%
26
Small Methods
26 papers in training set
Top 0.8%
0.9%
27
International Journal of Food Microbiology
11 papers in training set
Top 0.5%
0.8%
28
Journal of Microbiological Methods
11 papers in training set
Top 0.4%
0.8%
29
Environmental Science & Technology Letters
22 papers in training set
Top 0.4%
0.7%
30
Microbiome
139 papers in training set
Top 3%
0.7%