Show abstract

Focused ultrasound neuromodulation offers a promising noninvasive strategy for precise deep-brain stimulation, yet conventional piezoelectric phased arrays rely on bulky hardware, high-voltage electronics, and complex phase control, limiting their scalability and wearable integration. Photoacoustic approaches enable wireless ultrasound generation but remain constrained by a trade-off between focusing precision, penetration depth, and robustness to optical misalignment. Here, we present a geometrically encoded passive photoacoustic patch (PPP) based on a spherical double logarithmic spiral (SDLS) array that achieves intrinsically stable and programmable acoustic focusing without electronic phase modulation. By distributing hemispherical CNT/PDMS photoacoustic emitters quasi-uniformly over an equal-path spherical surface and orienting each emitter toward a predefined focal point, the device establishes geometry-dominated wavefront convergence. Numerical simulations demonstrate that curved geometry is a prerequisite for phase-free focusing, while the nonperiodic spiral topology suppresses sidelobes and mitigates interference artifacts Compared with continuous spherical or periodic concentric arrays, the SDLS architecture exhibits substantially enhanced robustness to optical axis displacement, reducing focal tilt from > 14{degrees} to approximately 5{degrees} under 2 mm lateral misalignment. Experimental three-dimensional hydrophone mapping confirms millimeter-scale focusing at approximately 7 mm depth with a full width at half-maximum of 1.3 mm and peak pressures up to 8 MPa under safe laser exposure ([≤] 20 mJ/cm2). The focal region can be continuously tuned by adjusting illumination aperture size without altering device geometry or excitation schemes. The patch demonstrates excellent thermal and acoustic stability during prolonged operation and enables region-specific motor cortex stimulation in vivo, eliciting distinct electromyographic responses in forelimb and hindlimb muscles. By shifting ultrasound beam formation from electronic phase control to intrinsic three-dimensional geometry, this work establishes a lightweight, wire-free, and optically programmable platform for robust wearable neuromodulation and scalable bioacoustic interfaces.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

1
Advanced Functional Materials
41 papers in training set
Top 0.1%
25.8%
2
Advanced Science
249 papers in training set
Top 0.3%
18.5%
3
Advanced Materials
53 papers in training set
Top 0.3%
9.1%
50% of probability mass above
4
Nature Communications
4913 papers in training set
Top 22%
8.4%
5
Nano Letters
63 papers in training set
Top 0.4%
6.3%
6
Advanced Healthcare Materials
71 papers in training set
Top 0.9%
2.1%
7
Science Advances
1098 papers in training set
Top 13%
2.1%
8
Nature Biomedical Engineering
42 papers in training set
Top 0.6%
1.9%
9
ACS Nano
99 papers in training set
Top 2%
1.9%
10
Small
70 papers in training set
Top 0.5%
1.7%
11
Lab on a Chip
88 papers in training set
Top 0.8%
1.3%
12
Advanced Materials Technologies
27 papers in training set
Top 0.4%
1.2%
13
Nature Nanotechnology
30 papers in training set
Top 0.9%
1.1%
14
Journal of Neural Engineering
197 papers in training set
Top 2%
0.9%
15
Proceedings of the National Academy of Sciences
2130 papers in training set
Top 41%
0.9%
16
Biofabrication
32 papers in training set
Top 0.6%
0.9%
17
Photoacoustics
11 papers in training set
Top 0.4%
0.8%
18
Biosensors and Bioelectronics
52 papers in training set
Top 1%
0.8%
19
IEEE Transactions on Biomedical Engineering
38 papers in training set
Top 0.9%
0.7%
20
ACS Sensors
45 papers in training set
Top 1%
0.7%
21
Biomaterials
78 papers in training set
Top 1%
0.7%
22
Scientific Reports
3102 papers in training set
Top 77%
0.7%
23
PLOS ONE
4510 papers in training set
Top 70%
0.7%