Portable Breathing Monitoring with Phase-Resolved Airflow Dynamics Enabled by a Dual-Response Flexible PZT Sensor
Li, M.; Aoyama, J.; Wu, Y.; Uchiyama, T.; Yoshikawa, K.; Mano, T.; Song, Y.; Zhang, H.
Show abstract
Respiratory monitoring in daily-life settings is important for health assessment, yet extracting physiologically interpretable information from breathing signals under natural conditions remains challenging, as breathing is inherently dynamic and strongly modulated by behavior. Here, a portable breathing monitoring device based on a flexible lead zirconate titanate sensor is developed to address this challenge. By exploiting polarity-opposed piezoelectric and pyroelectric responses through sensor orientation, the recorded breathing waveform exhibits a characteristic dual-component structure, consisting of a narrow transient spike followed by a broad quasi-steady peak within each breathing phase. This intrinsic waveform structure enables phase-resolved quantification of how breathing effort is distributed between transient and quasi-steady components during inhalation and exhalation. Pilot measurements in healthy subjects and patients with chronic obstructive pulmonary disease or asthma reveal systematic shifts toward transient-enhanced breathing in patients, providing clearer differentiation than conventional descriptors based on breathing duration or amplitude. By transforming complex breathing dynamics into stable and physiologically meaningful signal components under daily-life conditions, this dual-response sensing approach enables more robust access to function-related changes in natural breathing.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Clinical characterization of respiratory droplet production during common airway procedures using high-speed imaging 92%
- Performance of EasyBreath ® Decathlon Snorkeling mask for Delivering Continuous Positive Airway Pressure 92%
- Modeling of aerosol transmission of airborne pathogens in ICU rooms of COVID-19 patients with acute respiratory failure 92%
Similar papers in this journal
- Development and Clinical Validation of a Miniaturized Finger Probe for Bedside Hemodynamic Monitoring 90%
- Real-time Hearing Threshold Determination of Auditory Brainstem Responses by Cross-correlation Analysis 89%
- Facilitating clinically relevant skin tumor diagnostics with spectroscopy-driven machine learning 89%
Similar papers in this journal
- Quantifiable identification of flow-limited ventilator dyssynchrony with the deformed lung ventilator model 93%
- Comparing physiological impacts of positive pressure ventilation versus self-breathing via a versatile cardiopulmonary model incorporating a novel alveoli opening mechanism 89%
- Red blood cell passage through deformable interendothelial slits in the spleen: Insights into splenic filtration and hemodynamics 89%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.