Temporal evolution acquisition based arterial spin labeling (TEA-ASL) for accurate arterial blood T2 mapping
Sun, J.; Yuan, C.; Xu, J.; Zhu, J.; Wang, N.; Liu, Y.; Wei, Q.; Fang, W.; Chen, Z.; Wang, C.; Wang, H.; Jiang, D.; Hu, P.; Yan, F.; Li, H.; Shao, X.
Show abstract
Accurate quantification of arterial blood T2 can be useful for non-invasive assessment of blood oxygenation and blood-brain barrier (BBB) function. While arterial spin labeling (ASL) combined with multi-echo readouts offers a contrast-agent-free approach to map arterial blood T2, in vivo applications remain challenging due to rapid signal decay and low signal-to-noise ratio (SNR) at longer echo times (TEs), likely leading to overestimation of T2 values. We propose a novel temporal evolution acquisition based ASL (TEA-ASL) sequence incorporating an optimized variable refocusing flip angle (RFA) train to preserve signal across all TEs. Data were acquired on a 5T MRI system combining a pseudo-continuous ASL (pCASL) with the proposed TEA readout with 12 echo times (32-384 ms). The variable RFA scheme significantly improved signal stability across the echo train compared to conventional acquisition with constant RFAs. Accuracy and clinical feasibility of the proposed method was validated by simulations, phantom scans, in-vivo test/retest experiments and in a patient with middle cerebral artery stenosis. The proposed TEA-ASL technique provides robust arterial T2 mapping at ultra-high field, offering a promising tool for probing oxygenation-related hemodynamics and BBB-associated pathophysiology.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging 98%
- Single-shot Echo Planar Time-resolved Imaging for multi-echo functional MRI and distortion-free diffusion imaging 97%
- Bidirectional crusher gradient method for estimating the labeling efficiency of pseudo-continuous arterial spin labeling MRI in mice 97%
Similar papers in this journal
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 98%
- Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression 96%
- MRS-Sim: Open-Source Framework for Simulating Realistic In Vivo-like MR Spectroscopy Data 96%
Similar papers in this journal
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions 97%
- Accuracy and precision in super-resolution MRI: Enabling spherical tensor diffusion encoding at ultra-high b-values and high resolution 97%
- Cerebrospinal Fluid Flow within Ventricles and Subarachnoid Space Evaluated by Velocity Selective Spin Labeling MRI 97%
Similar papers in this journal
Similar papers in this journal
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 93%
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 93%
- Improved characterization of diffusion in normal and cancerous prostate tissue through optimization of the restriction spectrum imaging signal model 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.