Retest-Reliability of Cone and Rod Function Assessments in Pseudoxanthoma elasticum: PROPXE Study Report 3
Cancian, G.; Ansari, G.; Dysli, C.; Michels, S.; Feltgen, N.; Terry, S.; Pfau, M.; Pfau, K.
Show abstract
Purpose: To determine the test-retest reliability of visual function parameters in patients with genetically confirmed Pseudoxanthoma elasticum (PXE), as a necessary step toward evaluating their suitability as outcome measures in future therapeutic trials. Methods: In this prospective natural history study (PROPXE, ClinicalTrials.gov ID: NCT05662085), patients with PXE underwent comprehensive visual function evaluation in one study eye at baseline and at a month 2 retest visit. Functional testing included light- and dark-adapted steady state microperimetry and dark-adaptometry at 8{degrees}, 15{degrees} 30{degrees}, and 46{degrees} eccentricity. Test-retest reliability was evaluated using Bland-Altman statistics. Results: Twenty-six patients (14 female, 12 male; median [IQR] age 55 years [43; 59]) with genetically confirmed PXE were included in the study. Overall, the steady-state microperimetry limits of agreement (LoA) were {+/-}2 dB for mean sensitivity and {+/-}6.8 dB for pointwise sensitivity in both scotopic (cyan and red) and mesopic conditions. The LoAs of rod intercept time as a measure of dark adaptometry were {+/-} 12 min at the inner measurement points (8{degrees} and 15{degrees}) and {+/-} 18 min at the outer measurement points (30{degrees} and 46{degrees}). Conclusions: Scotopic and mesopic microperimetry LoAs are similar to earlier published test-retest analyses in other retinal diseases. Dark-adaptometry curve parameters were markedly more variable compared to previous data in healthy volunteers. This is likely attributable to the severe dark adaptation abnormalities in PXE, leading to long test durations. Translational Relevance: The evaluation of functional biomarkers is critical for designing future clinical trials aimed at slowing PXE progression.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Reliability of retinal pathology quantification in age-related macular degeneration: Implications for clinical trials and machine learning applications 98%
- Establishing Fully-Automated Fundus-Controlled Dark Adaptometry: A Validation and Retest-Reliability Study 98%
- Advanced Retinal Imaging and Ocular Parameters of the Rhesus Macaque Eye 97%
Similar papers in this journal
- Potential Structural Biomarkers in 3D Images Validated by the First Functional Biomarker for Early Age-Related Macular Degeneration - ALSTAR2 Baseline 97%
- Progressive dysmorphia of retinal pigment epithelium in age related macular degeneration revealed by fluorescence lifetime imaging 97%
- Association between Drusen Burden Determined by OCT and Genetic Risk in Early and Intermediate Age-Related Macular Degeneration 96%
Similar papers in this journal
- Macula structural and vascular differences in glaucoma eyes with and without high axial myopia 97%
- Automated Expert-level Scleral Spur Detection and Quantitative Biometric Analysis on the ANTERION Anterior Segment OCT System 96%
- Optic nerve tortuosity and displacements during horizontal eye movements in healthy and highly myopic subjects 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.