Back

Polyjet 3D printing of tissue-mimicking materials: how well can 3D printed synthetic myocardium replicate mechanical properties of organic myocardium?

Severseike, L.; Lee, V.; Bakken, C.; Brandon, T.; Bhatia, V.

2019-10-31 bioengineering
10.1101/825794 bioRxiv
Show abstract

Anatomical 3-D printing has potential for many uses in education, research and development, implant training, and procedure planning. Conventionally, the material properties of 3D printed anatomical models have often been similar only in form and not in mechanical response compared to biological tissue. The new Digital Anatomy material from Stratasys utilizes composite printed materials to more closely mimic the mechanical properties of tissue. Work was done to evaluate Digital Anatomy myocardium under axial loading for comparison with porcine myocardium regarding puncture, compliance, suturing, and cutting performance.\n\nIn general, the Digital Anatomy myocardium showed promising comparisons to porcine myocardium. For compliance testing, the Digital Anatomy was either within the same range as the porcine myocardium or stiffer. Specifically, for use conditions involving higher stress concentrations or smaller displacements, Digital Anatomy was stiffer. Digital Anatomy did not perform as strongly as porcine myocardium when evaluating suture and cutting properties. The suture tore through the printed material more easily and had higher friction forces both during needle insertion and cutting. Despite these differences, the new Digital Anatomy myocardium material was much closer to the compliance of real tissue than other 3D printed materials. Furthermore, unlike biological tissue, Digital Anatomy provided repeatability of results. For tests such as cyclic compression, the material showed less than two percent variation in results between trials and between parts, resulting in lower variability than tissue. Despite some limitations, the myocardium Digital Anatomy material can be used to configure structures with similar mechanical properties to porcine myocardium in a repeatable manner, making this a valuable research tool.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

1
Journal of the Mechanical Behavior of Biomedical Materials
24 papers in training set
Top 0.1%
19.2%
2
PLOS ONE
5266 papers in training set
Top 12%
15.6%
3
Acta Biomaterialia
92 papers in training set
Top 0.1%
11.0%
4
Annals of Biomedical Engineering
37 papers in training set
Top 0.1%
10.0%
50% of probability mass above
5
Journal of Biomechanical Engineering
20 papers in training set
Top 0.1%
7.0%
6
Bioengineering
29 papers in training set
Top 0.1%
4.2%
7
Frontiers in Bioengineering and Biotechnology
98 papers in training set
Top 0.6%
2.9%
8
Scientific Reports
3612 papers in training set
Top 46%
2.2%
9
Computer Methods and Programs in Biomedicine
28 papers in training set
Top 0.4%
1.7%
10
Computers in Biology and Medicine
128 papers in training set
Top 3%
1.6%
11
Journal of Biomechanics
64 papers in training set
Top 0.5%
1.6%
12
Biomechanics and Modeling in Mechanobiology
29 papers in training set
Top 0.3%
1.6%
13
Journal of Biomedical Materials Research Part A
20 papers in training set
Top 0.3%
1.2%
14
Journal of The Royal Society Interface
235 papers in training set
Top 3%
1.2%
15
International Journal for Numerical Methods in Biomedical Engineering
14 papers in training set
Top 0.2%
1.2%
16
Advanced Materials Technologies
29 papers in training set
Top 0.5%
1.0%
17
Royal Society Open Science
214 papers in training set
Top 6%
0.9%
18
Biology Open
156 papers in training set
Top 3%
0.9%
19
Computer Methods in Biomechanics and Biomedical Engineering
10 papers in training set
Top 0.2%
0.9%
20
Bioengineering & Translational Medicine
21 papers in training set
Top 0.5%
0.9%
21
PeerJ
308 papers in training set
Top 12%
0.6%
22
Biomaterials
84 papers in training set
Top 2%
0.5%
23
IEEE Transactions on Biomedical Engineering
40 papers in training set
Top 1%
0.5%
24
Journal of Visualized Experiments
34 papers in training set
Top 0.8%
0.5%