Blood pressure variability from intra-arterial recordings in humans
Subramani, S.; Mukadam, F. A.; Gangadharan, N.; Baskaran, B.; S, B.; Kandasamy, S.; Wankhar, S.; Devasahayam, S.
Show abstract
Systolic and diastolic blood pressures are reported as single point values by the non-invasive techniques used in clinical practice, while, in fact, they are highly varying signals. The objective of this study was to document the magnitude of variation of systolic and diastolic pressures over a few minutes by analysing intra-arterial pressure recordings made in 51 haemodynamically stable patients in an intensive care unit. Intra-arterial pressure data were acquired by a validated data acquisition system. Fast-Flush test was performed and the dynamic characteristics of the catheter transducer system namely natural frequency and damping co-efficient were calculated. Only those recordings with acceptable dynamic characteristics were included in the analysis. Power spectral calculation using the Discrete Fourier transform (DFT) of the pressure recording revealed two frequency peaks below the peak at heart rate. The lower and higher frequency peaks below the heart rate peak are referred to as Mayer and Traube waves in this study. Mayer wave peaks were observed in DFT spectra of 49 out of 51 patients. The Mayer wave frequency peaks ranged between 0.045 Hz to 0.065 Hz in 41 out of 51 patients. The frequency of Traube waves or the respiratory variations was more than 0.14 Hz. Three categories of systolic and diastolic pressure variabilities namely beat-to-beat variability, Respiratory variability (Traube wave amplitude) and Total magnitude of variation are reported for all 51 patients. The mean systolic and diastolic pressure variations (in a period of about 10 minutes) in the study sample were 21 {+/-} 9 mm Hg and 14 {+/-} 5 mm Hg respectively. Given the magnitude of systolic and diastolic pressure variations over a few minutes, the validity of reporting single point values for these pressures and using single point cut-offs for diagnosis and treatment of hypertension must be re-evaluated.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Feasibility of estimation of aortic wave intensity using non-invasive pressure recordings in the absence of flow velocity in man. 94%
- Effective Assessments of a Short-duration Poor Posture on Upper Limb Muscle Fatigue before Physical Exercise 92%
- Predictive modeling of secondary pulmonary hypertension in left ventricular diastolic dysfunction 92%
Similar papers in this journal
- The assessment of cortical hemodynamical responses induced by tubuloglomerular feedback using in vivo imaging 92%
- Sex Differences in Middle Cerebral Artery Reactivity and Hemodynamics Independent from Changes in Systemic Arterial Stiffness in Adult Sprague-Dawley Rats 92%
- Novel Application of a Force Sensor during Sit-to-Stands to Measure Dynamic Cerebral Autoregulation Onset 91%
Similar papers in this journal
- Comparison of feature-based indices derived from photoplethysmogram recorded from different body locations during lower body negative pressure 95%
- Noninvasive Assessment of Temporal Dynamics in Sympathetic and Parasympathetic Baroreflex Responses 93%
- The complex relationship between effort and heart rate: a hint from dynamical analysis 93%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.