Evaluation of the ELITe InGenius PCR assay compared with immunofluorescence for Pneumocystis jirovecii detection in respiratory samples
Datwyler, I.; Kuster, H.; Greiner, M.; Sauteur Patrick M., M.; Karrer, U.; Tschumi, F.; Berger, C.; Chakrakodi, B.; Bosshard, P. P.; Zinkernagel, A. S.; Kouyos, R. D.; Gunthard, H. F.; Brugger, S. D.
Show abstract
IntroductionPneumocystis jirovecii (PJ) causes pneumonia primarily in immunocompromised individuals. Although direct immunofluorescence (IF) remains the diagnostic standard, PCR assays are increasingly used because of higher sensitivity and reduced observer dependency. This study evaluates the ELITe InGenius PJ PCR assay compared with IF for PJ detection in respiratory specimens. Material and MethodsRespiratory samples submitted for IF-based PJ testing at the University Hospital Zurich over a 19-month period were retrospectively analyzed using the ELITe InGenius PCR assay. Diagnostic accuracy was assessed using IF as the reference method, and performance was evaluated by receiver operating characteristic (ROC) analysis. ResultsA total of 222 samples from 213 patients were included (70 sputum, 152 bronchoalveolar lavage). PCR and IF results were concordant in 160 (72.1%) specimens, including 18 positives and 142 negatives. Sixty-two (27.9%) samples were discrepant: six IF-positive/PCR-negative and 56 IF-negative/PCR-positive. IF reexamination was possible for IF-positive/PCR-negative and IF-negative/PCR-high-positive samples (>100,000 copies/ml or Ct <29), resulting in revised IF findings in 3/3 and 2/8 cases, respectively. Three IF-negative/PCR-positive cases were clinically confirmed as true infections. ROC analysis identified an optimal PCR threshold of 6,233 copies/ml, yielding 70.8% sensitivity and 88.3% specificity, improving to 82.6% and 89.5% after reexamination. DiscussionThese findings support the higher sensitivity of PCR relative to IF for direct PJ detection. Clinical confirmation of IF-negative/PCR-positive cases and known limitations of IF underscore the diagnostic value of the ELITe InGenius assay. Its performance supports its use in routine diagnostics to improve early detection and guide timely treatment.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Universal PCR for Bacteria, Mycobacteria, and Fungi: A 10-year Retrospective Review of Clinical Indications and Patient Outcomes 95%
- Assessment of the Clinical Utility of Plasma Metagenomic Next-Generation Sequencing in a Pediatric Hospital Population 94%
- Diagnostic accuracy of SARS-CoV-2 rapid antigen detection testing in symptomatic and asymptomatic children in the clinical setting 94%
Similar papers in this journal
- Evaluating the feasibility, sensitivity, and specificity of next-generation molecular methods for pleural infection diagnosis 95%
- Optimal processing of tongue swab samples for Mycobacterium tuberculosis detection by the Xpert MTB/RIF Ultra assay 94%
- Evaluation of flow cytometry for cell count and detection of bacteria in biological fluids. 94%
Similar papers in this journal
- Production and performance assessment of a SARS-CoV-2 biomimetic in a verification program for pandemic readiness 93%
- A comparative study of real-time RT-PCR based SARS-CoV-2 detection methods and its application to human derived and surface swabbed material 93%
- Association of COVID-19 RT-qPCR test false-negative rate with patient age, sex and time since diagnosis 92%
Similar papers in this journal
- The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients 95%
- Real-World Clinical Performance of the Abbott Panbio with Nasopharyngeal, Throat and Saliva Swabs Among Symptomatic Individuals with COVID-19 94%
- Sensitivity of nasopharyngeal, oropharyngeal and nasal washes specimens for SARS-CoV-2 detection in the setting of sampling device shortage 92%
Similar papers in this journal
- An optimized stepwise algorithm combining rapid antigen and RT-qPCR for screening of COVID-19 patients 95%
- Original research. Inhibition of Polymerase Chain Reaction: Pathogen-Specific Controls are better than Human Gene Amplification 95%
- Diagnostic accuracy of two commercial SARS-CoV-2 Antigen-detecting rapid tests at the point of care in community-based testing centers 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.