Validation of a New AI Seizure Detection Algorithm for Pre-term Neonates, Term Neonates and Infants
Gupta, A.; Tozzi, L.; Puranik, T.; Anand, S.; Juliano, C.; La Vega-Talbott, M.; Said, R. R.; Singh, A.; Sullivan, J. E.; Abend, N. S.; Hahn, C. D.; Kamousi, B.
Show abstract
Seizures are frequent in the first year of life and they are associated with increased risk of long-term neurological disability. Accurate diagnosis of seizures in neonates and infants requires continuous electroencephalogram (EEG) monitoring with expert interpretation. While rapid detection of seizures allows timely management and may influence neurodevelopmental outcomes, it may not be feasible in settings without round-the-clock expert interpretation. We evaluated the real-world performance of Clarity (Ceribell Inc.), a novel algorithm for automated seizure detection from EEG of preterm neonates, term neonates, and infants in a validation dataset of patients of postnatal age 0-1 years and gestational age 22-42 weeks who underwent continuous EEG monitoring at three hospitals in the United States. We quantified algorithm performance using the following metrics: (1) area under the curve for classification of 10-second EEG segments as seizure or no seizure; (2) sensitivity and false positives in detecting seizure episodes; and (3) sensitivity, specificity and negative/positive predictive value in identifying recordings where seizure duration reached or exceeded predetermined thresholds. The validation dataset consisted of 756 EEG recordings with a cumulative duration of 5230 hours (median: 2.94 hours, interquartile interval: 1.46-12.62 hours) from 167 preterm neonates, 323 term neonates, and 266 infants. A total of 568 seizures occurred in 75 recordings, with a cumulative seizure duration of 15.13 hours. The algorithm achieved an area under the curve of 0.96. The algorithm was correct 99-100% of the time when ruling out seizures in a recording. It correctly detected 75-83% of seizure episodes and identified 89-94% of recordings containing seizures. Performance was equivalent between preterm neonates, term neonates, and infants and across the three participating hospitals. Overall, the Clarity algorithm demonstrated high performance in detecting and ruling out seizures from EEG data in preterm neonates, term neonates, and infants across three hospitals. This demonstrates real-world feasibility and high reliability of automatic seizure detection with Clarity for continuous EEG monitoring in the first year of life.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
Similar papers in this journal
- Thalamic deep brain stimulation modulates circadian and infradian cycles of seizure risk in epilepsy 93%
- Dynamic network properties of the interictal brain determine whether seizures appear focal or generalised 92%
- Probabilistic comparison of gray and white matter coverage between depth and surface intracranial electrodes in epilepsy: a patient-specific modeling and empirical study 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.