Pathogenic PF4/Polyvinylsulfonate ELISA-negative Antibodies in HIT
kanack, a.; splinter, n.; mauch, e.; Tefera, L.; Reyes Gil, M.; Jasra, S.; Goodwin, A.; Smock, K.; Ahmad, H.; ashrani, A.; Robinson, N.; casanegra, a.; jones, c.; Pechauer, S.; yttre, e.; aster, r.; kohlhagen, m.; leger, R.; murray, d.; Zhou, L.; wang, D.; Wen, R.; chen, d.; pruthi, r.; Padmanabhan, A.
Show abstract
BACKGROUNDPlatelet factor 4-polyanion enzyme-linked immunosorbent assays (ELISAs) are considered highly sensitive for diagnosing heparin-induced thrombocytopenia (HIT), such that current practice guidelines recommend use of ELISA-negative results to exclude HIT. Once HIT is ruled out, alternative, non-heparin-based anticoagulant treatments are ceased, and heparin reintroduction frequently occurs. METHODSAntigen-based and PF4-dependent functional testing were used to study PF4/polyvinyl sulfonate ELISA-negative platelet-activating antibodies in HIT-suspected patients and mice immunized with PF4/heparin. RESULTSThree patients with clinical presentations consistent with HIT tested negative in an ELISA using PF4-polyvinylsulfonate (PF4/PVS), an antigenic target very commonly used for HIT antibody detection. All three patients demonstrated PF4-dependent platelet activation in functional testing that was sensitive to blockade of platelet Fc{gamma}RIIa receptors and inhibited by high concentrations of heparin, consistent with pathogenic HIT antibodies. Functional testing-based screening of 500 ELISA-negative patients identified three patients whose sera activated platelets in a PF4- and Fc{gamma}RIIa-dependent manner, and had clinical histories consistent with HIT. Five of the six ELISA-negative HIT patients were re-exposed to heparin, which precipitated a decrease in platelet counts in all re-exposed patients, and one patient developed a new thrombus. To advance the study of ELISA-negative HIT antibodies, mice were immunized with PF4/heparin, and functional and antigenic assays were simultaneously used to successfully identify an ELISA-negative, PF4-dependent platelet-activating murine monoclonal antibody that recapitulated the serological characteristics of ELISA-negative HIT patients. CONCLUSIONSRecognition of ELISA-negative HIT is critical to avoid harm due to the cessation of alternative anticoagulation therapy and re-exposure of these patients to heparin.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Platelet Activating Immune Complexes Identified in COVID-19 Associated Coagulopathy 97%
- Relieving platelet inhibition using a novel bi-specific antibody:A novel approach for circumventing the platelet storage lesion 95%
- POmAb, an antibody targeting open prothrombin, results in anticoagulation without excessive bleeding in mice 94%
Similar papers in this journal
- Sickle red blood cell derived extracellular vesicles activate endothelial cells and enhance sickle red cell adhesion mediated by von Willebrand factor 93%
- Platelet dysfunction in immune thrombocytopenia: finding clinical subsets with platelet phenotypes 93%
- Delayed-Phase Thrombocytopenia in Patients of Coronavirus Disease 2019 (COVID-19) 91%
Similar papers in this journal
- Antithrombotic Efficacy and Bleeding Risks of Vaccine-Induced Immune Thrombotic Thrombocytopenia Treatments 97%
- Altered fibrin clot structure contributes to thrombosis risk in severe COVID-19 92%
- Temporal in vivo platelet labelling in mice reveals age-dependent receptor expression and conservation of specific mRNAs 92%
Similar papers in this journal
- The GPIbα intracellular tail - role in transducing VWF- and Collagen/GPVI-mediated signaling 92%
- Post-translational polymodification of β1 tubulin regulates motor protein localisation in platelet production and function 91%
- Metabolic signatures of cardiorenal dysfunction in plasma from sickle cell patients, as a function of therapeutic transfusion and hydroxyurea treatment 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.