Voxel-Wise Quantification and Multi-planar Visualization of Plaque Contrast Enhancement in Intracranial Vessel Wall MRI
Guo, Y.; Wang, M.; Sun, B.; Cheng, D.; Wang, X.; Zhang, K.; Xia, J.; Canton, G.; Geleri, D. B.; Sun, J.; Balu, N.; Hatsukami, T. S.; Mossa-Basha, M.; Yuan, C.
Show abstract
BackgroundContrast enhancement (CE) of intracranial atherosclerotic plaques is a valuable biomarker for identifying culprit plaques in ischemic stroke, but current assessment methods are limited by qualitative approaches and artifact susceptibility. PurposeTo develop and validate a semi-automated method for visualization and quantification of CE intensity and volume, and evaluate its accuracy and scan-rescan reproducibility. Study typeRetrospective. PopulationTwo patient groups with intracranial atherosclerotic diseases were included: Group A (n=37, 82 plaques) for developing and validating the CE map against expert review, and Group B (n=11, 23 plaques) for assessing scan-rescan reproducibility. Field Strength/Sequence3.0 T, 3D time-of-flight gradient echo sequence and T1-weighted fast spin echo sequences, before and after Gadolinium contrast injection. AssessmentA 3D quantitative CE map was developed that incorporated dedicated multi-contrast, multi-planar preprocessing, image intensity normalization, adjustment for enhancement artifacts, and derivation of a signal intensity threshold. Statistical TestsReceiver operating characteristic curve analysis determined the optimal CE threshold. Sensitivity, specificity, and Cohens kappa assessed agreement between the quantitative CE map and manual review. Spearmans correlation evaluated CE volume quantification. Intraclass correlation coefficient (ICC) and coefficient of variance (CV) assessed reproducibility. ResultsThe optimal signal intensity threshold for post-contrast maps was 0.4 plus the median plaque wall intensity on pre-contrast maps. The area under the curve for CE detection was 0.91 (95% CI: 0.87-0.94), with sensitivity and specificity of 0.83 and 0.90. CE volume measurements strongly correlated with expert measurements (Spearmans rho=0.82, p<0.001). Enhancement ratio showed high reproducibility (ICC=0.92, 95% CI: 0.82-0.96), and CE detection demonstrated robust agreement (kappa=0.82, 95% CI: 0.55-1). Data ConclusionThe proposed CE map demonstrated good accuracy compared to expert review and high scan-rescan reproducibility, enabling comprehensive assessment of CE presence, intensity, and volume for evaluating plaque vulnerability in intracranial atherosclerotic disease.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Increased Brain Volumetric Measurement Precision from Multi-Site 3D T1-weighted 3T Magnetic Resonance Imaging by Correcting Geometric Distortions 95%
- Simulated Diagnostic Performance of Ultra-Low-Field MRI: Harnessing Open-Access Datasets to Evaluate Novel Devices 94%
- Tailored Magnetic Resonance Fingerprinting 93%
Similar papers in this journal
- Prospective Motion Correction and Automatic Segmentation of Penetrating Arteries in Phase Contrast MRI at 7 T 94%
- Highly Accelerated Vessel-Selective Arterial Spin Labelling Angiography using Sparsity and Smoothness Constraints 94%
- Neuroanatomical underpinning of diffusion kurtosis measurements in the cerebral cortex of healthy macaque brains 94%
Similar papers in this journal
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 93%
- AI-powered Gradient Echo Plural Contrast Imaging (AI-GEPCI): a Comprehensive Multiparametric Neurological Protocol from a Single MRI Scan 92%
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 92%
Similar papers in this journal
- Does contrast-enhancement improve visualisation of lenticulostriate arteries in cerebral small vessel disease using time-of-flight magnetic resonance angiography at 7 Tesla? 96%
- Image processing approaches to enhance perivascular space visibility and quantification using MRI 93%
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 93%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.