Back

An impactor-based aerosol platform for probing indoor, short-range transmission dynamics: a Phi6 bacteriophage study

Thirugnanasampanthar, M.; Gomez, M.; Kvitka, E.; Jackson, K.; Rhem, R. G.; Dolovich, M.; Hosseinidoust, Z.

2025-10-27 respiratory medicine
10.1101/2025.10.24.25338726 medRxiv
Show abstract

1.Short-range transmission is a driver of airborne disease spread. However, limited knowledge exists on the immediate impact of host, environmental, and seasonal factors on viable pathogen-laden droplets (VPLD) shortly after release. This work modelled the effects of respiratory droplet size, airway mucus composition, viral loads, and seasonal variations in indoor relative humidity (RH) on the number of VPLD collected shortly after equilibration. Clinically relevant concentrations of the SARS-CoV-2 surrogate bacteriophage, Phi6, were prepared in solutions reflecting the solute content of the airway mucus in healthy and disease states. Low solute levels and viral loads, characteristic of the presymptomatic phase, increased VPLD counts (initial diameter range, 5.59 to 20.28 {micro}m) under low indoor RH in temperate winter. Elevated solute levels and decreased viral loads, characteristic of the late symptomatic phase, reduced VPLD counts (initial diameter range, 1.73 to 20.28 {micro}m) under intermediate RH in temperate summers. High viral loads, characteristic of the early symptomatic phase, resulted in comparable VPLD counts (initial diameter range, 1.73 to 20.28 {micro}m) across solute levels and RH, indicating a buffering effect of high viral loads against inactivation. These findings, integrated with complementary lines of evidence, were used to describe potential mechanisms of short-range transmission dynamics. 3. SYNOPSISThis study investigated the effects of four factors including respiratory droplet size, mucus composition, viral load, and seasonal variations in indoor relative humidity, on the recovery of viable pathogen-laden droplets to understand short-range transmission dynamics.

Published in ACS ES&T Air · not in our set (fewer than 10 published preprints to learn from) · training set

Matching journals

The top 9 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.