Equity and feasibility of remote photoplethysmography for hypertension screening in darker-skinned populations in Nigeria: a multi-site field study
Dasa, D.; Davies, P.
Show abstract
ObjectiveTo evaluate the feasibility, diagnostic accuracy, and acceptability of a remote photoplethysmography (rPPG) blood pressure screening tool among adults with Fitzpatrick skin types V and VI in Kebbi State, Nigeria, with additional assessment of the influence of facial tribal markings and internet connectivity. MethodsWe enrolled 306 patients and 30 staff across three hospitals. rPPG blood pressure estimates (Lifelight app) were compared with OMRON M2 cuff measurements (reference standard; 140/90 mmHg thresholds). Outcomes included the proportion of participants for whom the tool produced a blood pressure estimate, agreement (Bland-Altman), diagnostic accuracy (sensitivity/specificity), and patient/staff perceptions. ResultsThe tool produced blood pressure estimates for 249 of 306 participants (81.4%), forming the analyzable index-test set. Agreement with the reference standard was limited (SBP MAE 15.37 mmHg, RMSE 19.93; DBP MAE 10.91 mmHg, RMSE 13.61). Within this set, sensitivity for hypertension detection was very low (SBP 0.04; DBP 0.10), with complete failure to detect elevated systolic blood pressure in Fitzpatrick type VI participants (sensitivity = 0.00). Specificity was higher (SBP 0.99; DBP 0.89). Performance was poorest in Fitzpatrick type VI. Lower bandwidth correlated with higher tool failure rates (maximum r = -0.69, minimum r = -0.51). Tribal markings were not associated with obtaining a reading, but subgroup accuracy differed (e.g., SBP bias -9.97 mmHg with marks). Despite these limitations, 70% of patients rated accuracy favourably and more than 90% of staff expressed willingness to adopt the tool, indicating a perception-performance gap. ConclusionRemote photoplethysmography was acceptable to patients and staff but is not recommended for population screening without further algorithmic and operational improvements. Despite high specificity (systolic 0.99), critically low sensitivity (systolic 0.04 overall, 0.00 for Fitzpatrick VI) means most hypertensive cases would be missed in screening programmes. Algorithmic refinement for darker skin tones and robust offline or low-bandwidth capability are prerequisites for equitable deployment in low-resource settings.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Automated Image Transcription for Perinatal Blood Pressure Monitoring Using Mobile Health Technology 95%
- Feasibility characteristics of wrist-worn fitness trackers in health status monitoring for post-COVID patients in remote and rural areas 92%
- QRS detection in single-lead, telehealth electrocardiogram signals: benchmarking open-source algorithms 91%
Similar papers in this journal
- bp: Blood Pressure Analysis in R 94%
- Comparison of WHO laboratory-based and non-laboratory-based CVD risk Charts among Hypertensive Adults Attending Primary Healthcare Centers in West Africa Sub-region 94%
- Empowering Healthcare Professionals in West Africa □ A Feasibility Study and Qualitative Assessment of a Dietary Screening Tool to Identify Adults at High Risk of Hypertension 94%
Similar papers in this journal
- Biometric linkage of longitudinally collected electronic case report forms and confirmation of subject identity: An open framework for ODK and related tools 93%
- Using wearable and nearable devices in telerehabilitation for COPD: A review of digital endpoints in home-based programs 91%
- Remote digital measurement of visual and auditory markers of Major Depressive Disorder severity and treatment response. 91%
Similar papers in this journal
- Assessing the Safety of Home Oximetry for Covid-19: A multi-site retrospective observational study 93%
- Telehealth versus Self-Directed Lifestyle Intervention to Promote Healthy Blood Pressure: A Protocol for a Randomized Controlled Trial 92%
- HEART rate variability biofeedback for LOng Covid symptoms (HEARTLOC): protocol for a feasibility study 92%
Similar papers in this journal
- Remote patient monitoring and digital therapeutics in heart failure: lessons from the Continuum pilot study 92%
- Improving emergency department patient-doctor conversation through an artificial intelligence symptom taking tool: an action-oriented design pilot study 91%
- Diagnosing Chronic Obstructive Airway Disease: a diagnostic accuracy study of a smartphone delivered algorithm combining patient-reported symptoms and cough analysis for use in acute care consultations. 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.