Back

Large field of view fluorescence imaging of microfluidic devices with a tandem-lens macroscope

Mokhtari, D. A.; Lashkaripour, A.; Fordyce, P. M.

2025-10-13 bioengineering
10.1101/2025.10.11.680838 bioRxiv
Show abstract

Microfluidic devices enable high-throughput sample processing with remarkable parallelization and miniaturization. While fluorescence microscopy provides a convenient method for reading out signal from microfluidic assays, commercially-available microscopes impose a fundamental tradeoff between temporal resolution, spatial resolution, and numerical aperture (NA). Spatially tiled imaging enables high-resolution and high-NA imaging over a large area but reduces temporal resolution. Conversely, low magnification, low NA imaging captures large areas in one shot, but typically sacrifices spatial resolution and fluorescence sensitivity. To address this, we introduce an automated transfluorescence tandem-macro-lens optomechanical system (macroscope) capable of sensitive, multi-channel fluorescence imaging over a very large field of view (34 mm diameter, 740 mm2), with resolution determined by the sensor pixel size. We demonstrate bright-field resolution of low-micron features and detection of low-to mid-nanomolar concentrations of common fluorophores within microfluidic device channels. To demonstrate the utility of this macroscope, we image enzyme turnover within valved microfluidic devices (the HT-MEK system, for High-Throughput Microfluidic Enzyme Kinetics) and achieve >50-fold increased temporal resolution over common commercial instruments while maintaining high sensitivity. This macroscope imaging solution costs substantially less than commercially available alternatives, providing a powerful new imaging approach for microfluidic applications requiring sensitive and rapid wide-field fluorescence imaging.

Published in Lab on a Chip (predicted rank #1) · training set

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

Lab on a Chip · published here
96 papers in training set
Top 0.1%
18.5%
2
Analytical Chemistry
218 papers in training set
Top 0.4%
8.9%
3
Biomedical Optics Express
95 papers in training set
Top 0.2%
7.9%
4
The Analyst
16 papers in training set
Top 0.1%
6.7%
5
Scientific Reports
3612 papers in training set
Top 16%
5.5%
6
ACS Sensors
49 papers in training set
Top 0.2%
5.2%
50% of probability mass above
7
Nature Communications
5641 papers in training set
Top 35%
3.2%
8
PLOS ONE
5266 papers in training set
Top 45%
2.1%
9
Nature Methods
385 papers in training set
Top 4%
2.1%
10
Communications Biology
993 papers in training set
Top 10%
2.1%
11
Biosensors and Bioelectronics
57 papers in training set
Top 0.4%
2.1%
12
Journal of Biomedical Optics
28 papers in training set
Top 0.2%
1.9%
13
Optica
27 papers in training set
Top 0.2%
1.9%
14
BMC Methods
15 papers in training set
Top 0.1%
1.7%
15
Methods
34 papers in training set
Top 0.3%
1.5%
16
Small
78 papers in training set
Top 1%
1.3%
17
Advanced Biology
29 papers in training set
Top 0.5%
1.1%
18
Optics Express
26 papers in training set
Top 0.2%
1.1%
19
SLAS Technology
14 papers in training set
Top 0.1%
1.1%
20
ACS Synthetic Biology
287 papers in training set
Top 2%
1.1%
21
ACS Omega
105 papers in training set
Top 2%
1.1%
22
ACS Photonics
13 papers in training set
Top 0.1%
1.1%
23
HardwareX
18 papers in training set
Top 0.2%
1.0%
24
Frontiers in Bioengineering and Biotechnology
98 papers in training set
Top 2%
1.0%
25
Journal of Microscopy
20 papers in training set
Top 0.2%
1.0%
26
Proceedings of the National Academy of Sciences
2444 papers in training set
Top 41%
0.8%
27
eneuro
439 papers in training set
Top 8%
0.8%
28
Science Advances
1243 papers in training set
Top 30%
0.8%
29
Advanced Materials Technologies
29 papers in training set
Top 0.5%
0.8%
30
Analytica Chimica Acta
17 papers in training set
Top 0.5%
0.8%