Accurate quantification of myocardial gadolinium-based contrast medium (CM) concentration is important for longitudinal cardiac MRI assessment. We developed a T1 mapping-based pharmacokinetic (PK) approach incorporating elastic deformation registration (ER) to improve fitting accuracy. Forty-nine participants (median age, 62 years) underwent native and dynamic T1 mapping at 2, 5, 9, and 15 minutes after CM administration. CM concentration maps for myocardium and blood pool were generated at each time point, with and without ER, and fitted to a PK model. Model performance was evaluated using the coefficient of determination (R{superscript 2}), Akaike Information Criterion (AIC), and Bayesian Information Criterion (BIC). Agreement between measured myocardial CM concentrations and model estimates was assessed, and the mean difference between them was calculated. T1-derived CM concentrations showed excellent agreement with phantom reference values (R2 = 0.999). ER improved model fit compared with no registration, with smaller absolute mean differences at all time points: 0.026 vs. 0.029 mM/l (2 min), -0.021 vs. -0.025 (5 min), -0.022 vs. -0.023 (9 min), and 0.018 vs. 0.021 mM/l (15 min). This ER-based dynamic T1 mapping approach improved the accuracy of PK modeling for myocardial CM concentration, supporting its potential utility for refined myocardial tissue characterization.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting improves intravoxel incoherent motion (IVIM) analysis in the human kidney 96%
- Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling 95%
- Bidirectional crusher gradient method for estimating the labeling efficiency of pseudo-continuous arterial spin labeling MRI in mice 95%
Similar papers in this journal
- Reproducibility of 4D Flow MRI-based Personalized Cardiovascular Models; Inter-sequence, Intra-observer, and Inter-observer variability 95%
- Transport Pathways and Kinetics of Cerebrospinal Fluid Tracers in Mouse Brain Observed by Dynamic Contrast-Enhanced MRI 94%
- Does contrast-enhancement improve visualisation of lenticulostriate arteries in cerebral small vessel disease using time-of-flight magnetic resonance angiography at 7 Tesla? 94%
Similar papers in this journal
- A novel model to quantify blood transit time in cerebral arteries using ASL-based 4D magnetic resonance angiography with example clinical application in moyamoya disease 94%
- 2-deoxy-D-glucose chemical exchange-sensitive spin-lock MRI of cerebral glucose metabolism after stroke in the rat 94%
- Optimal filtering strategies for task-specific functional PET imaging 93%
Similar papers in this journal
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 92%
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 92%
- Pancreas MRI segmentation into head, body, and tail enables regional quantitative analysis of heterogeneous disease 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.