Highly sensitive protein detection is critical in research and healthcare diagnostics but remains limited to resource intensive environments. In contrast, lateral flow immunoassay (LFIA)-based diagnostics are popular point-of-care tests due to their simplicity and user-friendly format but lack sensitivity for detecting the low concentrations of proteins that are present early in infections and among asymptomatic individuals. To overcome these limitations, we developed a novel biosensor platform utilizing antibody-initiated loop-mediated isothermal amplification (ai-LAMP) with an LFIA readout for protein detection. This platform integrates protein-specific antibody-antigen binding with the robust signal amplification of LAMP. By conjugating pairs of antibodies to overlapping DNA strands, the presence of a target protein brings the DNA strands into proximity, completing a DNA target to directly initiate the LAMP reaction without any additional ligation step. This approach facilitates the rapid detection of low concentration proteins with a clear visual readout and can be performed in 3 steps from sample to answer. Using ai-LAMP we detected HIV-1 p24 on commercially available LFIAs at a limit of detection (LOD) of 20 fM (0.53 pg/mL), demonstrating 46x improvement over existing HIV p24 LFIAs. The use of ai-LAMP eliminates the need for sophisticated laboratory equipment to detect protein targets in low concentrations, paving a new way for rapid and accessible biomarker detection in clinical and research settings. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=139 SRC="FIGDIR/small/678293v2_ufig1.gif" ALT="Figure 1"> View larger version (24K): org.highwire.dtl.DTLVardef@5b587forg.highwire.dtl.DTLVardef@10f3587org.highwire.dtl.DTLVardef@1833eeborg.highwire.dtl.DTLVardef@197d1bf_HPS_FORMAT_FIGEXP M_FIG C_FIG

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

1
Biosensors and Bioelectronics
52 papers in training set
Top 0.1%
34.0%
2
ACS Sensors
45 papers in training set
Top 0.1%
23.2%
50% of probability mass above
3
Analytical Chemistry
205 papers in training set
Top 0.5%
5.0%
4
The Analyst
15 papers in training set
Top 0.1%
3.8%
5
Lab on a Chip
88 papers in training set
Top 0.3%
3.7%
6
Nature Communications
4913 papers in training set
Top 46%
2.1%
7
ACS Nano
99 papers in training set
Top 2%
1.9%
8
Talanta
12 papers in training set
Top 0.3%
1.8%
9
Scientific Reports
3102 papers in training set
Top 56%
1.7%
10
Advanced Science
249 papers in training set
Top 12%
1.5%
11
ACS Applied Bio Materials
21 papers in training set
Top 0.5%
1.3%
12
PLOS ONE
4510 papers in training set
Top 61%
1.1%
13
Analytica Chimica Acta
17 papers in training set
Top 0.4%
1.0%
14
Sensors
39 papers in training set
Top 1%
1.0%
15
Nano Letters
63 papers in training set
Top 3%
0.8%
16
SLAS Technology
11 papers in training set
Top 0.2%
0.8%
17
ACS Central Science
66 papers in training set
Top 2%
0.8%
18
PLOS Neglected Tropical Diseases
378 papers in training set
Top 6%
0.7%
19
Viruses
318 papers in training set
Top 6%
0.7%
20
Virus Research
36 papers in training set
Top 1%
0.7%
21
Water Research
74 papers in training set
Top 2%
0.7%
22
npj Digital Medicine
97 papers in training set
Top 4%
0.7%
23
Nature Biotechnology
147 papers in training set
Top 8%
0.7%
24
Angewandte Chemie International Edition
81 papers in training set
Top 4%
0.5%