Exploring the Effect of LED-to-Photodetector Spacing on Subcutaneous Photoplethysmography for Continuous Blood Pressure Measurement
Cabal, D.; Nguyen, B.; Green, D. B.; Kilgore, K.; Thakkar, V.; Fu, M. J.; Majerus, S. J. A.
Show abstract
Photoplethysmography (PPG) is widely used to measure heart rate, blood oxygenation, and more recently, blood pressure. Implanted PPG systems offer the possibility to measure similar real-time measures of cardiovascular health, however, the detection method may vary due to a lack of capillary vessels for PPG sensors to observe in muscle tissue. To improve volumetric blood detection in large muscles, without relying on the capillary density of skin, a flexible PPG sensor was developed. The sensor included multiple spacing of illuminating infrared (IR) light emitting diodes (LEDs) and a single IR photodetector. This arrangement was expected to enable detection of blood volume changes at variable distances from the sensor face, potentially at much longer depths then feasible with skin-mounted PPG devices. IR bench phantoms simulating a large blood vessel embedded in IR absorbing, tissue-mimicking rubber were developed and used to determine the sensor performance in vitro. A preliminary in vivo test used an adult rabbit to provide additional performance validation. Test results reveal an observed trend of increased SNR for deeper vessel depths for the farthest LED to detector spacing which is aligned with our initial prediction. However, ANOVA and post-hoc tests reveal that these trends did not reach statistical significance. The in vivo test showed a relationship consistent with relevant literature. Future experiments are required to improve the phantoms representation of the biological setting and to confirm a reduced SNR variation for the farthest spacing. Clinical RelevanceDevelopment of a subcutaneous, continuous blood pressure sensor may provide benefits towards monitoring autonomic dysreflexia and hypertension for people affected by spinal cord injury.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, Fabrication, and Physiological relevancy 95%
- Open-Source Low-Cost Cardiac Optical Mapping System 94%
- Reliability and Performance of the IRRAflow® System for Intracranial Lavage and Evacuation of Hematomas - A Technical Note 93%
Similar papers in this journal
- Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents 94%
- A Block-Capable and Module-Extendable 4-Channel Stimulator for Acute Neurophysiology 94%
- Transcranial photoacoustic characterization of neurovascular physiology during early-stage photothrombotic stroke in neonatal piglets in vivo 92%
Similar papers in this journal
- A combined frequency domain near infrared spectroscopy and diffuse correlation spectroscopy system for comprehensive metabolic monitoring of inspiratory muscles during loading 93%
- Targeted spectroscopy in the eye fundus 93%
- Segmentation of the Urothelium in Optical Coherence Tomography Images with Dynamic Contrast 91%
Similar papers in this journal
- Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage 94%
- A scalable, multi-wavelength, broad bandwidth frequency-domain near-infrared spectroscopy platform for real-time quantitative tissue optical imaging 93%
- First-in-clinical application of a time-gated diffuse correlation spectroscopy system at 1064nm using superconducting nanowire single photon detectors 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.