Back

ISO-101, a Wrist-Worn Isometric Counter-Manoeuvre Device, Improves Blood Pressure Recovery in Orthostatic Hypotension

Connolly, L.; Smith, A.; Fawkes, N.; McGowan, I.; Frith, J.

2025-09-12 geriatric medicine
10.1101/2025.09.10.25335481 medRxiv
Show abstract

ISO-101 is a novel wrist-worn device designed to deliver guided upper-limb isometric counter-manoeuvres via a retractable resistance tether with visual feedback. This proof-of-concept study evaluated feasibility, safety and preliminary efficacy in adults with orthostatic hypotension (OH). In a fixed-sequence, within-participant design, each participant completed three active-stand assessments: unassisted; device activation while supine immediately before standing; and device activation immediately after standing. The primary outcome was the proportion of responders, defined a priori as achieving, with device use versus the unassisted condition, [≥]10 mmHg improvement in any one of resting blood pressure, nadir standing blood pressure at 30- 60 s, or reduction in the orthostatic blood-pressure drop (systolic or diastolic). The study was powered to test the responder proportion against a 20% benchmark derived from standard non-pharmacological care. Seventeen participants were enrolled (mean age 72 years; 77% male) and fourteen completed all assessments. Six of fourteen (43%) met the responder definition, exceeding the benchmark (exact binomial p=0.012). When the device was used immediately after standing, responders showed mean (SD) increases of +22.13 (16.29) mmHg systolic and +19.52 (12.47) mmHg diastolic compared with the unassisted stand; pre-stand activation yielded smaller, non-significant changes. No adverse events occurred. Usability was high, with 88% rating the device easy to use and 69% indicating they would use it in daily life. ISO-101 produced clinically meaningful improvements in orthostatic blood pressure in a substantial subset of patients, supporting progression to larger, controlled evaluations. WHAT IS ALREADY KNOWNO_LIOrthostatic hypotension (OH) is common and clinically significant, yet counter-manoeuvres are often poorly implemented in practice. C_LIO_LIWearable assistance for standardised counter-manoeuvres has not previously been tested in OH. C_LI WHAT THIS STUDY ADDSO_LIIn this proof-of-concept study, ISO-101, a guided wrist-worn device, achieved a clinically meaningful and statistically significant responder rate, exceeding that typically observed with standard care. C_LIO_LIResponders demonstrated marked increases in postural blood pressure, the device was rated as highly usable, and no adverse events were reported. C_LI HOW THIS STUDY MIGHT AFFECT RESEARCH, PRACTICE OR POLICYO_LIThese findings highlight the potential for wearable-assisted therapy in OH and support the need for further clinical evaluation. C_LI TRIAL REGISTRATION NUMBERClinicalTrials.gov: NCT06039410

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.