Fast and accurate measurement of small field dosimetry using a novel scintillation detector

Han, Y.; Xu, J.; Hao, Y.; Sun, B.

2025-08-26 radiology and imaging
10.1101/2025.08.22.25334184 medRxiv
Show abstract

BackgroundThe most used instruments for small-field dosimetry have notable limitations, including the need for correction factors, limited scanning speeds, and challenges in alignment for percentage depth dose (PDD) measurements, particularly for extremely small-fields. However, plastic scintillation detectors (PSDs) are an attractive alternative for small-field dosimetry due to their correction-free nature, linear dose response, and fast response time. PurposeThis study evaluates the robustness and accuracy of the dosimetric measurements using a new water-equivalent PSD in small-field dosimetry. The study also aims to report an indirect method for measuring PDD in small-fields, with a scanning time that is 5 to 10 times faster than traditional methods. MethodPDDs, profiles and output factors were measured on a Varian TrueBeam 6XFFF photon beam for the field size of 0.5x0.5 cm2, 1x1 cm2, 2x2 cm2, 3x3 cm2, 4x4 cm2 using a new PSD from Blue Physics (BP-PSD). These measurements were compared with those obtained using a well-established PSD (Standard Imaging W2), micro-diamond (TN60019, PTW-Freiburg, Germany), and micro-silicon detectors (TN60023, PTW-Freiburg, Germany). Owing to its fast response, the BP-PSD enabled the collection of beam profiles at 31 depths, which were used to derive the PDD while avoiding detector misalignment along the beam path. Data was collected in a water tank controlled by the PTW BeamScan software. The pulse-by-pulse raw data from BP-PSD were converted to respective dosimetry data using in-house software. ResultThe BP-PSD demonstrated excellent agreement with other detectors for small-field output factors (FOFs), with a maximum variation of 1.6%. The BP-PSD also showed strong agreements in PDD measurements with an ion chamber (TN31013) for both 3x3 cm2 and 10x10 cm2 field sizes, achieving a 98% gamma passing rate (gamma criteria: 1mm,3%). For the profile measurements, the BP-PSD showed consistency with both the micro-diamond and micro-silicon diode detectors, with less than 1% variation in measured penumbra length. At a 3x3 cm2 field size, the measured penumbra length (4 mm) agreed with previously published data (3.86-4.2 mm). Additionally, for field size less than 3x3 cm2 the indirect PDD measurements derived from profiles showed significant improvement compared to the direct measurements using various detectors, using TPS-calculated PDD as a reference. ConclusionThe BP-PSD has proven to be a robust and reliable detector for small-field dosimetry. It exhibits excellent agreement with other detectors in measuring small FOFs and provides accurate measurements with significantly faster scanning speeds in a water tank. The fast response feature enables the indirect PDD measurement method

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.