Pulse oximeter performance and skin pigment: comparison of 34 oximeters using current and emerging regulatory frameworks
Hughes, C.; Chen, D.; Law, T.; Bickler, P.; Feiner, J.; Shmuylovich, L.; Behnke, E.; Ortiz, L.; Leeb, G.; Auchus, I.; Negussie, F.; Bisegerwa, R.; Vargas Zamora, R.; Igaga, E.; Moore, K.; Okunlola, O.; Monk, E.; Fernandez, J. L.; Ehie, O.; Wilks, B.; Oyefeso, K.; Schornack, D.; Sendagire, C.; Lipnick, M.
Show abstract
BackgroundThe International Organization for Standardization (ISO) and US Food and Drug Administration (FDA) are updating regulations for pulse oximeters to reduce performance disparities linked to skin pigment. We tested common oximeters with current and anticipated regulatory frameworks. We hypothesized that not all oximeters show more positive bias in darkly vs lightly pigmented participants and that few oximeters would pass the anticipated FDA regulations. MethodsWe used a controlled desaturation protocol to test 34 oximeters across arterial oxygen saturations (SaO2) 70-100% in healthy adults. Based on what FDA and ISO had shared at the time of study design, we studied cohort sizes of [≥] 24 with [≥] 25% of participants being darkly pigmented. We used the subjective Monk Skin Tone (MST) scale and the objective individual typology angle (ITA) derived from a spectrophotometer to characterize skin pigment. The root mean square error (ARMS), bias (mean of SpO2 - SaO2 error), and skin pigment differential bias were calculated. Monte Carlo simulation explored potential impacts of participant selection on device passing. ResultsFor cohorts of 24 participants, 28/34 oximeters passed 2017 ISO Standard (ARMS [≤] 4%), 22/34 passed 2013 FDA guidance (ARMS [≤] 3%), 21/34 oximeters passed both ARMS and differential bias criteria for anticipated ISO standards, and 1/34 passed anticipated FDA criteria. More devices passed with cohorts > 24. Eleven oximeters had more positive bias in participants with dark vs. light (dorsal finger) pigmentation across 70-100% SaO2. Eighteen devices could pass or fail depending on cohorts selected for analysis. ConclusionsPulse oximeters show variable performance across manufacturers and models. Notably, only some devices show more positive bias in people with darker skin. Anticipated updates to ISO and FDA frameworks yield strikingly different assessments and require refinement of cohort sizes and differential bias criteria. Whether new guidelines will translate into improved real-world performance or reduced health disparities is yet to be determined.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- A combined frequency domain near infrared spectroscopy and diffuse correlation spectroscopy system for comprehensive metabolic monitoring of inspiratory muscles during loading 90%
- First in human measurements of abscess cavity optical properties and methylene blue uptake prior to photodynamic therapy by in vivo diffuse reflectance spectroscopy 90%
- The effects of skin tone on photoacoustic imaging and oximetry 90%
Similar papers in this journal
- Self-tests for COVID-19: what is the evidence? A living systematic review and meta-analysis (2020-2023) 87%
- Prediction models for post-discharge mortality among under-five children with suspected sepsis in Uganda: A multicohort analysis 87%
- Diagnostic testing preferences can help inform future public health response efforts: global insights from an international survey 87%
Similar papers in this journal
- Assessing the Safety of Home Oximetry for Covid-19: A multi-site retrospective observational study 90%
- Apple Watch and Withings Evaluation of Symptoms, Treatment, and Rhythm in those Undergoing Cardioversion (AWE STRUCk): A Pragmatic Randomized Controlled Trial 90%
- HEART rate variability biofeedback for LOng Covid symptoms (HEARTLOC): protocol for a feasibility study 89%
Similar papers in this journal
- Photoacoustic imaging to monitor outcomes during hyperbaric oxygen therapy: Validation in a small cohort and case study in a bilateral chronic ischemic wound 91%
- Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage 91%
- First-in-clinical application of a time-gated diffuse correlation spectroscopy system at 1064nm using superconducting nanowire single photon detectors 88%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.