Precise dose verification in proton therapy using Positron Emission Tomography.
Balcerzyk, M.; Freire, M.; Fernandez de la Rosa, R.; Pozo, M. A.; Smith, R. L.; Sanchez-Merino, G.; Gonzalez, A. J.
Show abstract
BackgroundProton and ion therapy have gained significant importance in radiation therapy cancer treatment due to their favorable dose distribution and tissue-sparing properties. In conventional gamma radiation therapy some methods of in vivo dose verification are possible with current medical devices. Proton and ion therapy dose verification is limited, mainly using PET for particle range. Prompt gamma methods offer low spatial resolution. This study presents initial results for in-vivo dose verification with PET imaging of F-18 during proton therapy. Although the activity concentration of F-18 generated by typical clinical doses (several Gy) is low, PET imaging performed approximately one hour post-irradiation yields sufficient image quality to derive dose-volume histograms (DVH), enabling spatial dose verification. PurposeTo verify the applied dose in proton therapy in vivo using Positron Emission Tomography with millimetric precision. Materials and MethodsWe simulated proton treatment in a brain phantom using Gate and RayStation platforms to assess the production of several positron emitting isotopes. We focused on the production of fluorine-18 (F-18), given its low positron energy, which enables accurate reproduction of the dose distribution. To evaluate the detectability of the anticipated low activity concentrations (on the order of a few Bq/mL) following a 3 Gy proton irradiation, we tested three PET systems: two preclinical scanners based on LYSO detectors and one clinical scanner based on BGO crystals. Finally, we have analyzed the dose-volume histograms for simulated and measured dose and activity distributions and compared them with the planned ones. ResultsF-18 PET imaging in proton therapy correlates with delivered dose within 5% error and matches the planned dose fall-off edge within 1 mm, enabling accurate and precise in vivo dose verification. ConclusionThe dose verification in proton therapy using F-18 Positron Emission Tomography allows higher precision of dose than other positron emitters like C-11, N-12 or O-15. 1 Key ResultsKey Results: In proton therapy, in-vivo F-18 production correlates with the deposited dose in the patient with a 5% margin of error. The leading-edge position of the F-18 activity distribution agrees with the planned dose fall off within 1 mm. Furthermore, the feasibility of detecting low activity concentrations typical of proton therapy (Bq/ml range) has been demonstrated using both preclinical and clinical PET scanners. 2 Required Summary StatementIn proton therapy the delivered dose to the patient can be measured in vivo using Positron Emission Tomography by imaging the production of F-18 isotope, achieving millimetric spatial accuracy.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Experimental investigation of oxygen diffusion in the peak and valley region of minibeam patterns during X-Ray irradiation 95%
- Cell lines of the same anatomic site and histologic type show large variability in intrinsic radiosensitivity and relative biological effectiveness to protons and carbon ions 94%
- Evaluation of inverse treatment planning for Gamma Knife radiosurgery using fMRI brain activation maps as organs at risk 94%
Similar papers in this journal
- Discordance in acute gastrointestinal toxicity between synchrotron-based proton and linac-based electron ultra-high dose rate irradiation 95%
- Cluster-Based Toxicity Estimation of Osteoradionecrosis via Unsupervised Machine Learning: Moving Beyond Single Dose-Parameter Normal Tissue Complication Probability by Using Whole Dose-Volume Histograms for Cohort Risk Stratification 94%
- Redefining FLASH RT: the impact of mean dose rate and dose per pulse in the gastrointestinal tract 94%
Similar papers in this journal
Similar papers in this journal
- Morphological changes after cranial fractionated photon radiotherapy: localized loss of white matter and grey matter volume with increasing dose 95%
- Development of a High-Performance Multiparametric MRI Oropharyngeal Primary Tumor Auto-Segmentation Deep Learning Model and Investigation of Input Channel Effects: Results from a Prospective Imaging Registry 92%
- Detection of Alteration in Carotid Artery Volumetry Using Standard-of-care Computed Tomography Surveillance Scans Following Unilateral Radiation Therapy for Early-stage Tonsillar Squamous Cell Carcinoma Survivors: A Cross-Sectional Internally-Matched Carotid Isodose Analysis 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.