Diagnostic accuracy of Clinical Radiology Reports for Trauma Radiographs: A retrospective validation study
Bruun, F. J.; Mueller, F. C.; Nybing, J. U.; Radev, D. I.; Honar, A. R.; Preuthun, J. R.; Laurberg, F. W.; Brejneboel, M. W.
Show abstract
Background/purposeDevelopment and validation of AI tools for diagnostic imaging requires high-quality annotations. Dedicated research readings are considered superior to the clinical radiologic report (CRR). However, the practices for generating CRR varies in rigor. The purpose of this study was to validate CRRs produced using a post-conference multiple disciplinary reader workflow by comparing them to dedicated research readings of trauma radiographs. Materials and MethodsThis retrospective study included consecutive patients referred for radiography at the indication of trauma at two university hospitals. For the index test, the CRRs were evaluated based on their description of eight common diagnoses. The reference standard was established as the agreement of two certified reporting technologists and arbitrated by a senior musculoskeletal radiologist. Sensitivity, specificity, positive and negative predictive values were calculated. ResultsThe study sample consisted of 618 consecutive examinations (median age 52 years IQR, 24, 76, 351 female). Fracture incidence was 36%. Incidence of other findings ranged from 1% (bone lesions) to 10% (degenerative disease). The sensitivities of the CRRs were: fracture (97% [94 to 99%]), luxation (87% [69 to 96%]), degenerative disease (67% [53 to 78%]), effusion (67% [46 to 83%]), old fracture (64% [48 to 78%]), subluxation (44% [14 to 79%]), halisteresis (30% [13 to 53%]) and bone lesion (25% [1 to 81%]). Specificity ranged from halisteresis (94% [92 to 96%]) to subluxation (100% [99 to 100%]) and luxation (100% [99 to 100%]). ConclusionWe found that the workflow at the tested hospitals generates clinical radiologic reports of trauma radiographs with a diagnostic accuracy for the assessment of fracture and luxation suitable for research quality labelling.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Investigating the relationship between internal spinal alignment and back shape in patients with scoliosis using PCdare: a comparative, reliability and validation study 96%
- A case-control study evaluating CT signs of xiphoid process associated with xiphodynia 94%
- Action observation intervention using three - dimensional movies improves the usability of hands with distal radius fractures in daily life: a nonrandomized controlled trial in women 94%
Similar papers in this journal
- Content-based image retrieval assists radiologists in diagnosing eye and orbital mass lesions in MRI 94%
- Image matters: Development of a novel staining method, the RGB-trichrome, as a reliable tool for the study of the musculoskeletal system 93%
- Modified FRAX Score for Prediction of Fall-induced Hip Fractures; The Added Value of Fall Energy, Number, and Social Vulnerability Index 93%
Similar papers in this journal
- Comparative Computed Tomography with Stress Manoeuvres for Diagnosing Distal Isolated Tibiofibular Syndesmotic Injury in Acute Ankle Sprain: a Protocol for an Accuracy-Test Prospective Study. 94%
- Validity of intraoperative imageless navigation (Naviswiss™) for component positioning accuracy in primary total hip arthroplasty: Protocol for a prospective observational cohort study in a single-surgeon practice 92%
- Exploring Risk Factors for Comorbid Depression in Osteoarthritis: A Scoping Review Protocol 91%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.