Back

Facilitating Multi-Center Consistency in PET/CT Assessment: Transferability and Harmonization of 3D-Printed Phantom Inserts

Nalla, S. K. K.; Maronnier, Q.; Palchan-Hazan, T.; Caselles, O.; Kennedy, J.

2025-05-31 radiology and imaging
10.1101/2025.05.30.25328639 medRxiv
Show abstract

BackgroundThree-dimensional printing has been used to build cost effective & realistic phantoms but their adaptability across facilities remains under-explored. Validation of standardization protocols and quantitative metrics of positron emission tomography (PET) to printed phantoms has been sparse. This study aims to evaluate the digital transferability of a multi-contrast phantom design and the quantitative consistency of metrics across two independent facilities, as a foundational step towards multi-centre standardization. MethodsCubic phantom inserts (40 mm) featuring spherical targets (0, 10, 15, and 20 mm), of a previously proven design, were fabricated at two different facilities using 3D printing and positioned within a Jaszczak phantom, filled with radiotracer and soap/water solution. Acquisitions (Day 0, 8) were performed on 5-ring Discovery MI and 32 cm OMNI Legend systems. Quantitative metrics, including CT Hounsfield units (HU), PET recovery coefficients (RC) and PET target-to-background ratios (TBR) were statistically analysed (rank sum tests) to assess the influence of facility, scanner model, and acquisition day. ResultsCT images revealed minor differences across facilities and scanners, with notable HU improvement (in emulating water) upon prolonged cube immersion. PET image quality was visually good with respect to desired feature representation. Average TBRMax (mean{+/-}std. dev.) were 1.56 {+/-} 0.03 (expected 2.0), 2.35 {+/-} 0.05 (expected 2.5), and 3.10 {+/-} 0.05 (expected 3.33). RCMax and RCMean ranged from 0.69 - 1.11 and 0.56 - 0.89. No statistical differences were found for TBRMax, RCMean, or RCMax (p [&ge;] 0.07 for Mann Whitney; p [&ge;] 0.57 for Friedman) and Bland-Altman mean bias < 10%. ConclusionOur study demonstrates that quantitative PET consistency can be reliably maintained across different facilities, printers, and scanners using 3D-printed phantoms produced from a common digital file. This confirmation of digital transferability offers a crucial and cost-effective framework for standardization, paving the way for more accessible multi-center harmonization studies.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.