Back

Application of Spectral Domain Optical Coherence Tomography To Guide Cochlear Implant Electrode Array

Jiramongkolchai, P.; Amaral, M. M.; Paul, R.; Matt, A.; Nie, M.; Hao, S.; Adkins, A.; Liang, H.; Holden, T.; Buchman, C.; Zhou, C.

2025-06-01 bioengineering
10.1101/2025.05.27.656464 bioRxiv
Show abstract

HypothesisA custom spectral domain optical coherence tomography (SD-OCT) platform can be used for real-time guidance of a cochlear implant electrode array (EA). BackgroundWith current cochlear implant surgical techniques, placement of the EA is a blind maneuver in which the surgeon relies on tactile feedback as the EA advances through the cochlear lumen. Cochlear implant trauma is a leading factor for poor speech performance outcomes and loss of residual hearing following surgery. Optical coherence tomography (OCT) is a non-invasive imaging modality that provides real-time visualization of tissue microstructure at higher spatial resolutions compared to clinical CT and MRI. Already adopted as standard of care in ophthalmology, OCT has the potential to assist the surgeon in real-time visualization of the EA trajectory. Unlike commercial systems, our custom OCT system allows tailored wavelength, scanning geometry, and real-time processing, which are critical factors for navigating the compact anatomy of the facial recess to image the cochlea. MethodsA custom-built SD-OCT system was used to image cochlear microanatomy in mice and human cadaveric temporal bones. The OCT system was then used to guide a mock EA in human cadaveric temporal bones in real-time using individual B scans that were reviewed sequentially as the EA was being advanced through the round window. ResultsUsing our OCT system, high-resolution (< 5.0 m) images of cochlear microanatomy were obtained in both mice and cadaveric human temporal bones with an image sensitivity of [~]104 dB. Following cochleostomy in cadaveric temporal bones, real-time sequential OCT B-scans were used to reliably guide placement of the EA through the scala tympani. ConclusionOur custom-built SD-OCT platform can generate high-resolution real-time visualization and orientation of mammalian cochlear microanatomy that can be used to assist with real time guidance of a CI EA. This technology has the potential to serve as a real-time surgical image guidance tool to minimize EA trauma and further our understanding of human cochlear pathophysiology.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

1
Journal of the Association for Research in Otolaryngology
15 papers in training set
Top 0.1%
32.1%
2
PLOS ONE
5266 papers in training set
Top 18%
10.1%
3
Translational Vision Science & Technology
39 papers in training set
Top 0.1%
8.1%
50% of probability mass above
4
Scientific Reports
3612 papers in training set
Top 14%
5.7%
5
Hearing Research
54 papers in training set
Top 0.2%
5.0%
6
Ear & Hearing
17 papers in training set
Top 0.1%
4.5%
7
Journal of Neural Engineering
221 papers in training set
Top 0.9%
3.6%
8
The Journal of the Acoustical Society of America
35 papers in training set
Top 0.1%
3.4%
9
British Journal of Ophthalmology
14 papers in training set
Top 0.2%
1.8%
10
Biomedical Optics Express
95 papers in training set
Top 0.6%
1.8%
11
Chemical Senses
32 papers in training set
Top 0.1%
1.8%
12
Frontiers in Neuroscience
256 papers in training set
Top 4%
1.5%
13
Trends in Hearing
15 papers in training set
Top 0.1%
1.5%
14
Investigative Ophthalmology & Visual Science
25 papers in training set
Top 0.3%
1.2%
15
Bioengineering
29 papers in training set
Top 0.7%
1.2%
16
Annals of Biomedical Engineering
37 papers in training set
Top 1%
0.9%
17
Neurophotonics
42 papers in training set
Top 0.5%
0.9%
18
Applied Sciences
25 papers in training set
Top 1%
0.6%
19
Current Protocols
15 papers in training set
Top 0.3%
0.6%
20
Journal of Biomedical Optics
28 papers in training set
Top 0.4%
0.6%
21
IEEE Transactions on Biomedical Engineering
40 papers in training set
Top 1%
0.5%
22
Journal of Visualized Experiments
34 papers in training set
Top 0.8%
0.5%
23
Annals of Clinical and Translational Neurology
34 papers in training set
Top 1%
0.5%
24
Experimental Eye Research
32 papers in training set
Top 0.5%
0.5%
25
Journal of Biophotonics
16 papers in training set
Top 0.4%
0.5%