Back

Minimally invasive and in situ capacitive sensing of cardiac biomarker from interstitial fluid

Mirzajani, H.; Zolfaghari, P.; Koca, B. Y.; Urey, H.

2025-05-18 bioengineering
10.1101/2025.05.14.654153 bioRxiv
Show abstract

Current diagnostic approaches for myocardial infarction (MI) rely on blood-based cardiac biomarker analysis by centralized instruments, often delaying timely clinical decisions. We present a microneedle-based capacitive biosensor (MiCaP) for in situ, minimally invasive monitoring of cardiac troponin I (cTnI) in interstitial fluid (ISF) for point-of-care (POC) applications. MiCaP is a label-free biosensor operating based on non-faradaic sensing by monitoring electric double layer capacitance at the microneedle-ISF interface. We extracted a simplified equivalent circuit model for MiCaP inserted into skin, confirming that the measured capacitance variations originate from cTnI binding to surface-immobilized antibodies. MiCaP was fabricated using a scalable process and functionalized with anti-cTnI antibodies. In vitro measurements showed a dynamic detection range of 10 pg/mL to 10 ng/mL, a limit of detection (LOD) of 3.27 pg/mL, and a total assay turnaround time of less than 15 minutes. A spike-and-recovery test using cTnI-spiked human serum yielded a recovery accuracy exceeding 93%. In vivo studies in rats demonstrated ISF cTnI levels of 3 {+/-} 0.4 pg/mL in controls and 912 {+/-} 683 pg/mL in experimental animals, indicating an increasing trend consistent with serum concentrations measured using a clinical immunoassay. These results support the potential of MiCaP as a minimally invasive biosensing platform for cardiac biomarker monitoring, with possible extension to multiplexed ISF-based diagnostics in POC.

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

1
Biosensors and Bioelectronics
52 papers in training set
Top 0.1%
29.8%
2
ACS Sensors
45 papers in training set
Top 0.1%
24.3%
50% of probability mass above
3
Advanced Materials
53 papers in training set
Top 0.6%
4.6%
4
ACS Nano
99 papers in training set
Top 0.8%
4.5%
5
Advanced Science
249 papers in training set
Top 4%
4.3%
6
Sensors
39 papers in training set
Top 0.5%
3.5%
7
Advanced Healthcare Materials
71 papers in training set
Top 0.8%
2.2%
8
Lab on a Chip
88 papers in training set
Top 0.5%
2.2%
9
Nano Letters
63 papers in training set
Top 1%
2.2%
10
Scientific Reports
3102 papers in training set
Top 53%
1.9%
11
Advanced Functional Materials
41 papers in training set
Top 1%
1.8%
12
PLOS ONE
4510 papers in training set
Top 62%
1.0%
13
Materials Today Bio
18 papers in training set
Top 0.4%
1.0%
14
npj Digital Medicine
97 papers in training set
Top 3%
0.8%
15
Journal of Nanobiotechnology
10 papers in training set
Top 0.2%
0.8%
16
Biomaterials
78 papers in training set
Top 1%
0.8%
17
ACS Applied Bio Materials
21 papers in training set
Top 0.8%
0.8%
18
Optics Express
23 papers in training set
Top 0.4%
0.8%
19
ACS Biomaterials Science & Engineering
37 papers in training set
Top 0.9%
0.8%
20
Advanced Materials Technologies
27 papers in training set
Top 0.7%
0.7%
21
The Analyst
15 papers in training set
Top 0.6%
0.7%
22
Analytical Chemistry
205 papers in training set
Top 3%
0.5%
23
Nature Biomedical Engineering
42 papers in training set
Top 3%
0.5%