Amorphous silicon resistors enable smaller pixels in photovoltaic retinal prosthesis
Shin, A.; Jensen, N.; Butt, E.; An, J.; Pham-Howard, D.; Galambos, L.; Mathieson, K.; Kamins, T.; Palanker, D.
Show abstract
ObjectiveClinical trials of the photovoltaic subretinal prosthesis PRIMA demonstrated feasibility of prosthetic central vision with resolution matching its 100{micro}m pixel size. To improve prosthetic acuity further, pixel size should be decreased. However, there are multiple challenges, one of which is related to accommodating a compact shunt resistor within each pixel that discharges the electrodes between stimulation pulses and helps increase the contrast of the electric field pattern. Unfortunately, standard materials used in integrated circuit resistors do not match the resistivity required for small photovoltaic pixels. Therefore, we used a novel material - doped amorphous silicon (a-Si) and integrated it into photovoltaic arrays with pixel sizes down to 20{micro}m. ApproachTo fit within a few {micro}m2 area of the pixels and provide resistance in the M{Omega} range, the material should have sheet resistance of a few hundred k{Omega}/sq, which translates to resistivity of a few {Omega}*cm. The a-Si layer was deposited by low-pressure chemical vapor deposition (LPCVD) and its resistivity was adjusted by PH3 doping before encapsulating the resistors between SiO2 and SiC for stability in-vivo. Main ResultsHigh-resolution retinal implants with integrated shunt resistors were fabricated with values ranging from 0.75 to 4 M{Omega} on top of the photovoltaic pixels of 55, 40, 30 and 20 {micro}m in size. Photoresponsivity with all pixel sizes was approximately 0.53 A/W, as high as in the arrays with no shunt resistor. The shunts shortened electrodes discharge time, with the average electric potential in electrolyte decreasing by only 21-31% when repetition rate increased from 2 to 30 Hz, as opposed to a 54-55% decrease without a shunt. Similarly, contrast of a Landolt C pattern increased from 16-22% with no shunt to 22-34% with a shunt. Further improvement in contrast is expected with pillar electrodes and local returns within each pixel. SignificanceMiniature shunt resistors in a MOhm range can be fabricated from doped a-Si in a process compatible with manufacturing of photovoltaic arrays. The shunt resistors improved current injection and spatial contrast at video frame rates, without compromising the photoresponsivity. These advances are critical for scaling pixel sizes below 100 {micro}m to improve visual acuity of prosthetic vision.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Cost-efficient boundary-free surface patterning achieves high effective-throughput of time-lapse microscopy experiments 91%
- A framework to enhance the Signal-to-Noise Ratio for quantitative fluorescence microscopy 91%
- Evaluating sources of technical variability in the mechano-node-pore sensing pipeline and their effect on the reproducibility of single-cell mechanical phenotyping 90%
Similar papers in this journal
- Portable Six-Channel Laser Speckle System for Simultaneous Cerebral Blood Flow and Volume Measurement with Potential Application for Characterization of Brain Injury 92%
- Foundry-fabricated dual-color nanophotonic neural probes for photostimulation and electrophysiological recording 92%
- Implantable photonic neural probes for light-sheet fluorescence brain imaging 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.