Elevated hydrostatic pressure acts via piezo-1 to destabilise VE-cadherin junctions: an endothelium-on-chip study
Bathrinarayanan, P. V.; Abadie, T.; Esteban, P. P.; Vigolo, D.; Simmons, M. J. H.; Grover, L. M.
Show abstract
Despite the effects of shear stress on endothelial biology having been extensively researched, the effects of hydrostatic vascular pressure at extremely low shear stresses have been largely ignored. In the current study, we employ a microfluidic organ-on-chip platform to elucidate the time and shear stress dependent effects of elevated hydrostatic pressure on endothelial junctional perturbations. We report that short term (1h) exposure to elevated hydrostatic pressure at high shear stress (1 dyne/cm2) but not low shear stress (0.1 dyne/cm2) caused VE-cadherin to form serrated, finger like projections at the cell-cell junctions and this effect was abrogated upon pharmacologically inhibiting piezo-1 mechanosensory protein. Interestingly, prolonged exposure (24h) to elevated hydrostatic pressure at low (0.1 dyne/cm2) but not high shear stress (1 dyne/cm2) caused VE-cadherin internalisation, thereby increasing the cytoplasmic concentration. Further, we report that this internalisation of VE-cadherin was reversible upon pharmacologically inhibiting piezo-1 in a time-dependent manner wherein after 12h, we observed stable VE-cadherin junctions re-appear at the cell-cell junctions. Overall, we demonstrate that piezo-1 plays a crucial role in the mechanotransduction of elevated hydrostatic pressure by regulating the VE-cadherin dynamics at cell-cell junctions. Targeting piezo-1 may provide a novel therapeutic/diagnostic marker, especially in conditions that involve microvascular dysfunction due to elevated vascular pressures.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Fluid Flow Impacts Endothelial-Monocyte Interactions in a Model of Vascular Inflammatory Fibrosis 93%
- Directed biomechanical compressive forces enhance fusion efficiency in model placental trophoblast cultures 92%
- Polyacrylamide Bead Sensors for in vivo Quantification of Cell-Scale Stress in Zebrafish Development 92%
Similar papers in this journal
- Biomechanical characterization of endothelial cells exposed to shear stress using acoustic force spectroscopy 94%
- Recapitulation of human embryonic heart beating to promote differentiation of hepatic endoderm to hepatoblasts 92%
- Low-Intensity Ultrasound Lysis of Amyloid Microclots in a Lab-on-Chip Model 91%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.