Chronic adaptive versus conventional deep brain stimulation in Parkinson's disease: a blinded randomized pilot trial
Isaias, I. U.; Marceglia, S.; Borellini, L.; Mailand, E.; Cogiamanian, F.; Barbieri, S.; Ampollini, A.; Pirola, E.; Remore, L.; Caffi, L.; Palmisano, C.; Baiata, C.; Bonvegna, S.; Romito, L.; Eleopra, R.; Levi, V.; Bentivoglio, A. R.; Piano, C.; Zibetti, M.; Lopiano, L.; Lanotte, M. M.; Mandat, T.; Tamma, F.; Arlotti, M.; Conti, C.; Rossi, L.; Foffani, G.; Lozano, A. M.; Moro, E.; Volkman, J.; Locatelli, M.; Priori, A.
Show abstract
BackgroundAdaptive deep brain stimulation (aDBS) is becoming a feasible therapeutic option in patients who are candidates for DBS, and implantable devices are now commercially available. We present the results of a blinded, randomized, crossover pilot trial aimed at comparing aDBS with conventional DBS (cDBS). MethodsFifteen patients were implanted with the AlphaDBS device (Newronika SpA, Milan, Italy, NCT04681534). The device replaced a previous Medtronic Activa PC at battery depletion in 11 patients, while the other four were first-time implant patients. Patients underwent two study phases: 1) a two-day, short-term follow-up in the hospital, in which patients received aDBS and cDBS for one day each (in random order); 2) a one-month, long-term follow-up at home, with patients receiving both DBS modes, each for two weeks. Safety endpoints were the occurrence of stimulation-related adverse events and the total electrical energy delivered to the tissue. The clinical endpoints were the Unified Parkinsons (part III) and Dyskinesia Disease Rating Scales used for in-clinic evaluation, and a three-day diary used for home assessment to estimate good on time without troublesome dyskinesia. At the end of the study, patients blindly decided their preferred stimulation mode. FindingsNo related adverse events were reported. The AlphaDBS device reliably recorded deep brain signals and applied a linear algorithm that changed the stimulation current every minute based on the average local field potential amplitude, calculated in a patient-specific beta frequency range. In the short-term follow-up, aDBS improved patients as much as cDBS, with lower UDysRS scores. In the long-term follow up, considering intra-patient differences, aDBS provided greater benefit than cDBS in 80% of patients. The same percentage of patients preferred and continued with aDBS (mean follow-up 316 days). InterpretationOur results suggest that aDBS is safe and effective and can be applied in a large population of parkinsonian patients who are candidates for DBS. The majority of patients improved more with aDBS than cDBS, who subjectively preferred aDBS in the long term. Further research is needed to better understand the profile of the best responders and the scheduling of aDBS.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Long-term effects of directional deep brain stimulation in Parkinson's disease: a randomized clinical trial on motor and non-motor symptoms 97%
- Remote Real Time Digital Monitoring fills a Critical Gap in the Management of Parkinson’s disease 94%
- Microstructure predicts non-motor outcomes following Deep Brain Stimulation in Parkinson’s disease 93%
Similar papers in this journal
- Network fingerprint of stimulation induced speech impairment in essential tremor 95%
- Differential cognitive effects of unilateral left and right subthalamic nucleus deep brain stimulation for Parkinson disease 95%
- Multimodal Image Guidance in Subthalamic Deep Brain Stimulation for Parkinson's Disease 94%
Similar papers in this journal
- Physiological effects of dual target DBS in an individual with Parkinson’s Disease and a sensing-enabled pulse generator 95%
- Neurohistopathological Findings of the Brain Parenchyma After Long-Term Deep Brain Stimulation: Case Series and Systematic Literature Review 95%
- A Pilot Interventional Study on Feasibility and Effectiveness of the CUE1 device in Parkinson’s disease 94%
Similar papers in this journal
Similar papers in this journal
- Automated Deep Brain Stimulation programming based on electrode location – a randomized, cross-over trial using a data-driven algorithm 98%
- Acute effects of Adaptive Deep Brain Stimulation in Parkinson's disease 95%
- Human Applications of Transcranial Temporal Interference Stimulation: A Systematic Review 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.