Facial video photoplethysmography for measuring average and instantaneous heart rate: a pilot validation study
Pstras, L.; Okupnik, T.; Ponikowska, B.; Paleczny, B.
Show abstract
IntroductionVideo photoplethysmography (vPPG) is a contactless optical technique of recording blood pulsations in the skin vasculature using a digital camera, which is increasingly used to measure or estimate various physiological parameters. Here, we evaluate the accuracy of heart rate (HR) measurements performed using facial vPPG technology Shen.AI Vitals and a smartphone camera. MethodsWe studied 35 healthy volunteers in a sitting position (median age 25 years, 17 females). Video recordings of participants faces were obtained using the front camera of a smartphone mounted on a tripod. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference HR values (average value from the entire 60-second measurement and multiple values averaged over 10-second or 4-second periods during the measurement). ResultsThe mean absolute errors were 0.1, 0.2, and 0.4 beats per minute (bpm) for HR averaged over 60-second, 10-second, and 4-second periods, respectively. The errors did not exceed 1 bpm in 100.0%, 99.8%, and 94.5% of cases, respectively. Regardless of the HR averaging time, the correlation between the vPPG-based and reference values was very strong (r > 0.99, P < 0.001). ConclusionsIn predominantly young, white, sitting subjects, the tested vPPG technology provided highly accurate HR values, both when averaging over 60 seconds as well as in the case of short-term averages over 10 seconds or instantaneous HR values averaged over 4 seconds. The results should be confirmed in a larger study with greater diversity in age, skin tone, and lighting conditions.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Comparison of wearable and clinical devices for acquisition of peripheral nervous system signals 97%
- In-Ear SpO2: A Tool for Wearable, Unobtrusive Monitoring of Hypoxaemia in COVID-19 95%
- Feasibility of Ultra-Short Term Analysis of Heart Rate and Systolic Arterial Pressure Variability at Rest and During Stress via Time-domain and Entropy-based Measures 94%
Similar papers in this journal
Similar papers in this journal
- An Open-Access Simultaneous Electrocardiogram and Phonocardiogram Database 96%
- Comparison of feature-based indices derived from photoplethysmogram recorded from different body locations during lower body negative pressure 96%
- High-Fidelity Measurement of Pulse Arrival Time in Critically Ill Children Using Standard Bedside Monitoring Equipment 94%
Similar papers in this journal
- Effective Assessments of a Short-duration Poor Posture on Upper Limb Muscle Fatigue before Physical Exercise 93%
- Comparisons of Heart Rate Variability Responses to Head-up Tilt With and Without Abdominal and Lower-Extremity Compression in Healthy Young Individuals: A Randomized Crossover Study 92%
- Early Prediction of Hemodynamic Shock in the Intensive Care Units with Deep Learning on Thermal Videos 92%