Cardiac diffusion kurtosis imaging in the human heart in vivo using 300mT/m gradients
Afzali, M.; coveney, S.; Mueller, L.; Jones, S.; Fasano, F.; Evans, C. J.; Teh, I.; Dall'Armellina, E.; Szczepankiewicz, F.; Jones, D. K.; Schneider, J. E.
Show abstract
PurposeDiffusion tensor imaging (DTI) is commonly used in cardiac diffusion magnetic resonance imaging (dMRI). However, the tissues microstructure (cells, membranes, etc.) restricts the movement of the water molecules, making the spin displacements deviate from Gaussian behaviour. This effect may be observed with diffusion kurtosis imaging (DKI) using sufficiently high b-values (b > 450 s/mm2), which are presently outside the realm of routine cardiac dMRI due to the limited gradient strength of clinical scanners. The Connectom scanner with Gmax = 300 mT/m enables high b-values at echo times (TE) similar to DTI on standard clinical scanners, therefore facilitating cardiac DKI in humans. MethodsCardiac-gated, second-order motion-compensated dMRI was performed with bmax = 1350 s/mm2 in 10 healthy volunteers on a 3T MRI scanner with Gmax = 300 mT/m. The signal was fitted to a cumulant expansion up to and including the kurtosis term and diffusion metrics such as fractional anisotropy (FA), mean diffusivity (MD), mean kurtosis (MK), axial kurtosis (AK), and radial kurtosis (RK) were calculated. ResultsWe demonstrate deviation of the signal from monoexponential decay for b-values > 450 s/mm2 (MK = 0.32 {+/-} 0.03). Radial kurtosis (RK = 0.35 {+/-} 0.04) was observed slightly larger than axial kurtosis (AK = 0.27 {+/-} 0.02), and the difference is statistically significant (RK - AK = 0.08 {+/-} 0.04, p = 2e - 4). ConclusionThis work demonstrates the feasibility of quantifying kurtosis effect in the human heart in vivo (at an echo time shorter than typical TEs reported for cardiac DTI), using high-performance gradient systems (which are 4-8 times stronger than on standard clinical scanners). Our work lays the foundation for exploring new biomarkers in cardiac dMRI beyond DTI.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Investigation of diffusion time dependence of apparent diffusion coefficient and intravoxel incoherent motion parameters in the human kidney 97%
- Bidirectional crusher gradient method for estimating the labeling efficiency of pseudo-continuous arterial spin labeling MRI in mice 97%
- Combined Angiographic, Structural and Perfusion Radial Imaging using Arterial Spin Labeling 97%
Similar papers in this journal
- 31P Transversal Relaxation Times and Metabolite Concentrations in the Human Brain at 9.4T 96%
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 95%
- Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression 95%
Similar papers in this journal
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 95%
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 94%
- T2-weighted T1 mapping and automated segmentation of CSF: Assessment of solute gradients in the healthy brain 93%
Similar papers in this journal
- Analysis of physiological noise in quantitative cardiac magnetic resonance 95%
- Acceleration of chemical shift encoding-based water fat MRI for liver proton density fat fraction and T2* mapping using compressed sensing 95%
- Freewater EstimatoR using iNtErpolated iniTialization (FERNET): Toward Accurate Estimation of Free Water in Peritumoral Region Using Single-Shell Diffusion MRI Data 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.