A Method for Sensitivity Analysis of Automatic Contouring Algorithms Across Different MRI Contrast Weightings Using SyntheticMR
McCullum, L.; Belal, Z.; Floyd, W.; Ali, A. M. S.; West, N.; Mulder, S.; Ding, Y.; Xu, J.; Thill, D.; O'Connell, N.; Stancanello, J.; Wahid, K. A.; Fuentes, D. T.; Hwang, K.-P.; Fuller, C. D.
Show abstract
BackgroundCurrently, a majority of institution-specific automatic MRI-based contouring algorithms are trained, tested, and validated on one contrast weighting (i.e., T2-weighted), however their actual performance within this contrast weighting (i.e., across different repetition times, TR, and echo times, TE) is under-investigated and poorly understood. As a result, external institutions with different scan protocols for the same contrast weighting may experience sub-optimal performance. PurposeThe purpose of this study was to develop a method to evaluate the robustness of automatic contouring algorithms to varying MRI contrast weightings. MethodsOne healthy volunteer and one patient was scanned using SyntheticMR on the MR-Simulation device. The parotid and submandibular glands in these subjects were contoured using an automatic contouring algorithm trained on T2-weighted MRIs. For ground truth manual contours, two radiation oncology residents and one pre-resident physician were recruited and their STAPLE consensus was determined. A total of 216 different MRI TR and TE combinations were simulated across T1-, T2-, and PD-weighted contrast ranges using SyntheticMRs post-processing software, SyMRI. Comparisons between automatic contouring algorithm contours and the ground truth were determined using the Dice similarity coefficient (DSC) and 95th percentile Hausdorff distance (HD95). ResultsNotable differences in the automatic contouring models performance were seen across the contrast-weighted range, even within the T2-weighted range. Further, some models even performed as well or better across subsets of the T1-weighted range. The PD-weighted range saw the worst performance. The range of discrepancy in DSC and HD95 exceeded 0.2 and 3.66 mm, respectively, in some structures. In the T2-weighted contrast region where the model was trained, 100%, 40%, 24%, and 57% for the DSC in the left parotid, right parotid, left submandibular, and right submandibular gland, respectively, exceeded interobserver variability. ConclusionsThis study demonstrates the variable performance of MRI-based automatic contouring algorithms across varying TR and TE combinations. This methodology could be applied in future studies as a method for evaluating model sensitivity, out of distribution detection ability, and performance drift.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Quality Assurance Assessment of Intra-Acquisition Diffusion-Weighted and T2-Weighted Magnetic Resonance Imaging Registration and Contour Propagation for Head and Neck Cancer Radiotherapy 96%
- Necessity and Impact of Specialization of Large Foundation Model for Medical Segmentation Tasks 95%
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 94%
Similar papers in this journal
Similar papers in this journal
- Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting improves intravoxel incoherent motion (IVIM) analysis in the human kidney 95%
- Multi-center benchmarking of cervical spinal cord RF coils for 7 T MRI: A traveling spines study 94%
- Image- vs. histogram-based considerations in semantic segmentation of pulmonary hyperpolarized gas images 94%
Similar papers in this journal
- Automated cervix biometry, volumetry and normative models for 3D motion-corrected T2-weighted 0.55-3T fetal MRI during 2nd and 3rd trimesters 94%
- Association of Graph-based Spatial Features with Overall Survival Status of Glioblastoma Patients 94%
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 93%
Similar papers in this journal
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 94%
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 94%
- Improved characterization of diffusion in normal and cancerous prostate tissue through optimization of the restriction spectrum imaging signal model 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.