Back

Evaluation of Photon-Counting CT for Spectral Imaging in Cardiovascular Applications: Impact of Lumen Size, Dose, and Patient Habitus

Rybertt, M. V.; Liu, L. P.; Mathew, M.; Sahbaee, P.; Litt, H. I.; Noel, P. B.

2025-01-08 radiology and imaging
10.1101/2025.01.07.25320150 medRxiv
Show abstract

ObjectivesThis study evaluates the performance of a clinical dual-source photon-counting computed tomography (PCCT) system in quantifying iodine within calcified vessels, using 3D- printed phantoms with vascular-like structures lined with calcium. MethodsParameters assessed include lumen diameters (4, 6, 8, 10, and 12 mm), phantom sizes (S: 20x20 cm, M: 25x25 cm, L: 30x40 cm, XL: 40x50 cm, representing the 99th percentile of US patient sizes), and iodine concentrations (2, 5, and 10 mg/mL). Scans were performed at radiation dose levels of 5, 10, 15, and 20 mGy to systematically evaluate iodine quantification accuracy and spectral imaging performance. ResultsThe results indicate that for lumen diameters [≥]6 mm, iodine quantification remains stable across all dose levels and phantom sizes, with deviations consistently below 0.6 mg/mL. Whereas, for 4 mm lumens, stability is observed primarily in smaller to medium phantoms, highlighting the influence of patient size and radiation dose on quantification accuracy. Virtual Monoenergetic Imaging (VMI) at 70 keV showed stable performance for larger lumens ([≥]6 mm) with variations of 13 {+/-} 2 HU across all conditions, while smaller lumens remained stable in medium to small phantoms. ConclusionsThese findings highlight the influence of lumen diameter, patient size, and radiation dose in optimizing PCCT protocols for spectral imaging. Importantly, the study demonstrates that PCCT delivers stable and highly accurate imaging across nearly the entire range of patient sizes in the U.S.. Advances in knowledgeThis study demonstrates PCCTs potential to enhance spectral imaging in vascular applications, surpassing conventional or Dual Energy CT.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

1
Medical Physics
14 papers in training set
Top 0.1%
18.6%
2
Physics in Medicine & Biology
18 papers in training set
Top 0.1%
18.6%
3
Scientific Reports
3612 papers in training set
Top 3%
12.0%
4
PLOS ONE
5266 papers in training set
Top 23%
7.3%
50% of probability mass above
5
European Radiology
15 papers in training set
Top 0.1%
5.2%
6
Photoacoustics
12 papers in training set
Top 0.1%
3.3%
7
Journal of Medical Imaging
11 papers in training set
Top 0.1%
3.2%
8
Diagnostics
50 papers in training set
Top 0.8%
2.4%
9
Journal of Magnetic Resonance Imaging
16 papers in training set
Top 0.2%
2.1%
10
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.1%
2.1%
11
Biomedical Physics & Engineering Express
11 papers in training set
Top 0.2%
1.9%
12
Biomedical Optics Express
95 papers in training set
Top 0.6%
1.7%
13
Magnetic Resonance in Medicine
85 papers in training set
Top 0.4%
1.7%
14
NMR in Biomedicine
28 papers in training set
Top 0.3%
1.3%
15
Cureus
68 papers in training set
Top 3%
1.3%
16
Archives of Clinical and Biomedical Research
28 papers in training set
Top 0.7%
1.1%
17
Journal of Biomedical Optics
28 papers in training set
Top 0.3%
1.1%
18
Computers in Biology and Medicine
128 papers in training set
Top 4%
1.0%
19
Magnetic Resonance Imaging
23 papers in training set
Top 0.4%
1.0%
20
Analytical Biochemistry
26 papers in training set
Top 0.5%
0.8%
21
European Journal of Nuclear Medicine and Molecular Imaging
20 papers in training set
Top 0.2%
0.8%
22
BMJ Open
601 papers in training set
Top 13%
0.8%
23
Annals of Biomedical Engineering
37 papers in training set
Top 1%
0.8%
24
International Journal of Radiation Oncology*Biology*Physics
25 papers in training set
Top 0.5%
0.6%
25
NeuroImage
903 papers in training set
Top 6%
0.6%
26
Nature Communications
5641 papers in training set
Top 59%
0.6%