A Low-Cost Markerless motion capture system to automate Functional Gait Assessment: Feasibility Study
Darici, O.; Cabak, C.; Wong, J. D.
Show abstract
Functional gait assessments in older adults have traditionally required manual in-person quantification of clinical measures such as walking speed and step placement. This reliance on individuals trained in motion analysis hinders the frequency with which they are performed, and reduces their generalizability and replicability. To standardize, simplify, and broaden access to gait assessments we here deploy recently-developed open-source tools to produce a low-cost, AI driven markerless motion capture system with custom analysis software for Functional Gait Assessment. Our system uses 3 Cameras, and was validated with a traditional marker-based system on subjects (N=3), showing strong correlation to laboratory-standard measures of step length (R2=0.98), step width (R2=0.97), and head speed (R2=0.95). The markerless systems FGA reports demonstrated data similar to previous FGA findings in older adult subjects (N=5). Moreover, supplemental standard biomechanical gait measures Step Width, walking Duration, and continuous Gait Speed may be integrated to augment existing FGA. This study demonstrates a proof-of-principle open-source markerless system for analyses of functional gait.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Inter-session repeatability of markerless motion capture gait kinematics 96%
- Validation, characterization, and utility of markerless motion capture in a large cohort of pediatric patients with complex gait patterns 96%
- Instrumented immobilizing boot quantifies reduced Achilles tendon loading during gait 95%
Similar papers in this journal
- Inertial sensor-based centripetal acceleration as a correlate for lateral margin of stability during walking and turning 97%
- Application of a novel force-field to manipulate the relationship between pelvis motion and step width in human walking 95%
- Continuous Monitoring of Head Turns: Compliance, Kinematics, and Reliability of Wearable Sensing 95%
Similar papers in this journal
- Using force data to self-pace an instrumented treadmill and measure self-selected walking speed 96%
- OpenSense: An open-source toolbox for Inertial-Measurement-Unit-based measurement of lower extremity kinematics over long durations 95%
- Optimized hip-knee-ankle exoskeleton assistance at a range of walking speeds 95%
Similar papers in this journal
- Validation of a smartphone embedded inertial measurement unit for measuring postural stability in older adults 96%
- The importance of a consistent workflow to estimate muscle-tendon lengths based on joint angles from the conventional gait model 94%
- Differences in centre of mass measurements between markerless and marker-based motion capture systems during balance and mobility assessments in individuals with chronic and sub-acute stroke 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.