Asymmetric spin echo multi-echo echo planar imaging (ASEME-EPI) sequence for pre-clinical high-field fMRI
Johnson, K. A.; Nencka, A. S.; Pawela, C. P.; Sidabras, J. W.
Show abstract
In functional magnetic resonance imaging (fMRI) of the blood oxygen level-dependent (BOLD) contrast, gradient-recalled echo (GRE) acquisitions offer high sensitivity but suffer from susceptibility-induced signal loss and lack specificity to microvasculature. In contrast, spin echo (SE) acquisitions provide improved specificity at the cost of reduced sensitivity. This study introduces Asymmetric Spin Echo Multi-Echo Echo Planar Imaging (ASEME-EPI), a technique designed to combine the benefits of both GRE and SE for high-field preclinical fMRI. ASEME-EPI employs a spin echo readout followed by two asymmetric spin echo (ASE) GRE readouts, providing an initial T2-weighted SE image and subsequent T2*-weighted ASE images. A feasibility study for the technique was implemented on a 9.4 T pre-clinical MRI system and tested using a visual stimulation in northern tree shrews. Comparing ASEME-EPI with conventional GRE echo planar imaging (GRE-EPI) and SE echo planar imaging (SE-EPI) acquisitions, results showed that ASEME-EPI achieved BOLD contrast-to-noise ratio (CNR) comparable to GRE-EPI while offering improved specificity in activation maps. ASEME-EPI activation was more confined to the primary visual cortex (V1), unlike GRE-EPI which showed activation extending beyond anatomical boundaries. Additionally, ASEME-EPI demonstrated the ability to recover signal in areas of severe field inhomogeneity where GRE-EPI suffered from signal loss. The performance of ASEME-EPI is attributed to its multi-echo nature, allowing for SNR-optimized combination of echoes, effectively denoising the data. The inclusion of the initial SE also contributes to signal recovery in areas prone to susceptibility artifacts. This feasibility study demonstrates the potential of ASEME-EPI for high-field pre-clinical fMRI, offering a promising compromise between GRE sensitivity and SE specificity while addressing challenges of T2* decay at high field strengths.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Comparison of BOLD and CBV using 3D EPI and 3D GRASE for cortical layer fMRI at 7T. 97%
- Attenuation of Motion Artifacts in fMRI using Discrete Reconstruction of Irregular fMRI Trajectories (DRIFT) 96%
- Single-shot Echo Planar Time-resolved Imaging for multi-echo functional MRI and distortion-free diffusion imaging 96%
Similar papers in this journal
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 96%
- Deep-Learning-Based Accelerated and Noise-Suppressed Estimation (DANSE) of quantitative Gradient Recalled Echo (qGRE) MRI metrics associated with Human Brain Neuronal Structure and Hemodynamic Properties 95%
- Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression 95%
Similar papers in this journal
- Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses 97%
- Slice-direction geometric distortion evaluation and correction with reversed slice-select gradient acquisitions 97%
- Feasibility of spiral fMRI based on an LTI gradient model 97%
Similar papers in this journal
- Sub-millimetre resolution laminar fMRI using Arterial Spin Labelling in humans at 7T 97%
- Analysis of physiological noise in quantitative cardiac magnetic resonance 95%
- Freewater EstimatoR using iNtErpolated iniTialization (FERNET): Toward Accurate Estimation of Free Water in Peritumoral Region Using Single-Shell Diffusion MRI Data 95%
Similar papers in this journal
- Framewise multi-echo distortion correction for superior functional MRI 96%
- Visual stimulus-evoked blood velocity responses in individual human posterior cerebral arteries measured with dynamic phase-contrast functional MR angiography 95%
- Multi-echo Acquisition and Thermal Denoising Advances Precision Functional Imaging 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.