PurposeWe aim to implement a 3D DWI sequence and show its usage on patients with new ischemic lesions. Materials and MethodsThe proposed 3D DWI sequence was implemented by integrating second-order gradient moment nulling (M2) and cardiac motion synchronization (Sync). All data were acquired on a 3T MAGNETOM Prisma scanner (Siemens Healthcare, Erlangen, Germany) using a 64 channel head and neck coil. 21 healthy volunteers underwent 3D DWI scans at 0.9 mm isotropic resolution using four motion compensation methods for comparison: no compensation (M0), M2 only, Sync only and the proposed M2+Sync method. 2D phase variation maps with different motion compensation methods were also acquired for one subject to illustrate the mechanism of the proposed method. A ghost-to-signal ratio (GSR) and blurring index was defined and compared among the four methods with repeated measures ANOVA and Tukeys test. 3D DWI was compared with 2D DWI for ADC quantification. Image quality and ischemic lesion conspicuity were evaluated with 12 patients after endovascular treatment. >ResultsWhole brain 3D DWI was achieved at 0.9 mm isotropic resolution within 5 minutes using the proposed sequence. M2+Sync achieved the lowest level of GSR and blurring along the slice direction. ADC quantification showed no statistically significant difference between M2+Sync compared to 2D DWI. 3D DWI showed similar image quality, higher lesion conspicuity and counts compared to 2D DWI. ConclusionDirect 3D DWI can be achieved by the combination of second order gradient moment nulling and cardiac synchronization.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Investigation of diffusion time dependence of apparent diffusion coefficient and intravoxel incoherent motion parameters in the human kidney 96%
- Prospective Motion Correction and Automatic Segmentation of Penetrating Arteries in Phase Contrast MRI at 7 T 96%
- Bidirectional crusher gradient method for estimating the labeling efficiency of pseudo-continuous arterial spin labeling MRI in mice 96%
Similar papers in this journal
- A Phantom System Designed to Assess the Effects of Membrane Lipids on Water Proton Relaxation 94%
- Age and gender dependence of liver diffusion parameters and the evidence of intravoxel incoherent motion modelling of perfusion component is constrained by diffusion component. 94%
- Band-selective IR PRESS for brain tumor spectroscopy allows robust detection of lactate 94%
Similar papers in this journal
- Tailored Magnetic Resonance Fingerprinting 96%
- Increased Brain Volumetric Measurement Precision from Multi-Site 3D T1-weighted 3T Magnetic Resonance Imaging by Correcting Geometric Distortions 95%
- Simulated Diagnostic Performance of Ultra-Low-Field MRI: Harnessing Open-Access Datasets to Evaluate Novel Devices 95%
Similar papers in this journal
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 95%
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 94%
- AI-powered Gradient Echo Plural Contrast Imaging (AI-GEPCI): a Comprehensive Multiparametric Neurological Protocol from a Single MRI Scan 94%
Similar papers in this journal
- Differentiation of white matter histopathology using b-tensor encoding and machine learning 95%
- Increased brain coverage and efficiency when measuring current-induced magnetic fields by use of simultaneous multi-slice echo-planar MRI 94%
- Freewater EstimatoR using iNtErpolated iniTialization (FERNET): Toward Accurate Estimation of Free Water in Peritumoral Region Using Single-Shell Diffusion MRI Data 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.