Flexible Copper Foil Sheet Receive Coil Array for MRI
Thompson, E. R.; Chen, L. W.; Miller, A. J. V.
Show abstract
This study presents the development and evaluation of a 16-channel general-purpose MRI coil array constructed using 50-micron copper foil sheets. The coils were rapidly manufactured using a die cut process and assembled into a square-shaped array designed for flexible, high-performance imaging. The copper foil coil demonstrated superior signal-to-noise ratio (SNR), lower noise correlation, and better parallel imaging performance compared to a commercially available 16-channel flexible coil. Phantom testing showed a 17-20% improvement in SNR with the copper foil coil, while noise correlation matrices indicated reduced interference between coil elements. In vivo testing further validated the coils performance, with higher SNR and enhanced image quality observed in axial and sagittal scans. The use of copper foil sheets, which are widely available and cost-effective, enabled rapid production of the coils without compromising quality. This approach offers significant advantages over existing flexible coil technologies that rely on more complex and expensive materials, such as copper threads and liquid metal. The ability to quickly tailor these coils for specific patient needs makes them particularly suitable for clinical applications where flexibility and speed are essential. The results of this study suggest that copper foil-based coils represent a promising solution for improving the accessibility, adaptability, and performance of MRI technology in a cost-effective manner.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Multi-center benchmarking of cervical spinal cord RF coils for 7 T MRI: A traveling spines study 97%
- A Numerical Alternative to MR Thermometry for Safety Validation of Multi-Channel RF Transmit Coils 97%
- Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T 96%
Similar papers in this journal
Similar papers in this journal
Similar papers in this journal
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 94%
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 93%
- The effect of device configuration and patient body composition on image artifact and RF heating of deep brain stimulation devices during MRI at 1.5T and 3T 92%
Similar papers in this journal
- Improved 7 Tesla Transmit Field Homogeneity with Reduced Electromagnetic Power Deposition Using Coupled Tic Tac Toe Antennas 96%
- Temporal signal-to-noise changes in combined multiband- and slice-accelerated echo-planar imaging with a 20- and 64-channel coil 94%
- Non-Invasive Perfusion MR Imaging of the Human Brain via Breath-Holding 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.