Deep Learning-powered CT-less Multi-tracer Organ Segmentation from PET Images: A solution for unreliable CT segmentation in PET/CT Imaging
Salimi, Y.; Mansouri, Z.; Shiri, I.; Mainta, I.; Zaidi, H.
Show abstract
IntroductionThe common approach for organ segmentation in hybrid imaging relies on co-registered CT (CTAC) images. This method, however, presents several limitations in real clinical workflows where mismatch between PET and CT images are very common. Moreover, low-dose CTAC images have poor quality, thus challenging the segmentation task. Recent advances in CT-less PET imaging further highlight the necessity for an effective PET organ segmentation pipeline that does not rely on CT images. Therefore, the goal of this study was to develop a CT-less multi-tracer PET segmentation framework. MethodsWe collected 2062 PET/CT images from multiple scanners. The patients were injected with either 18F-FDG (1487) or 68Ga-PSMA (575). PET/CT images with any kind of mismatch between PET and CT images were detected through visual assessment and excluded from our study. Multiple organs were delineated on CT components using previously trained in-house developed nnU-Net models. The segmentation masks were resampled to co-registered PET images and used to train four different deep-learning models using different images as input, including non-corrected PET (PET-NC) and attenuation and scatter-corrected PET (PET-ASC) for 18F-FDG (tasks #1 and #2, respectively using 22 organs) and PET-NC and PET-ASC for 68Ga tracers (tasks #3 and #4, respectively, using 15 organs). The models performance was evaluated in terms of Dice coefficient, Jaccard index, and segment volume difference. ResultsThe average Dice coefficient over all organs was 0.81{+/-}0.15, 0.82{+/-}0.14, 0.77{+/-}0.17, and 0.79{+/-}0.16 for tasks #1, #2, #3, and #4, respectively. PET-ASC models outperformed PET-NC models (P-value < 0.05). The highest Dice values were achieved for the brain (0.93 to 0.96 in all four tasks), whereas the lowest values were achieved for small organs, such as the adrenal glands. The trained models showed robust performance on dynamic noisy images as well. ConclusionDeep learning models allow high performance multi-organ segmentation for two popular PET tracers without the use of CT information. These models may tackle the limitations of using CT segmentation in PET/CT image quantification, kinetic modeling, radiomics analysis, dosimetry, or any other tasks that require organ segmentation masks.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 98%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 95%
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 95%
Similar papers in this journal
Similar papers in this journal
- Automated Long Axial Field of View PET Image Processing and Kinetic Modelling with the TurBO Toolbox 95%
- Validation of cardiac image derived input functions for functional PET quantification 94%
- Co-clinical FDG-PET Radiomic Signature in Predicting Response to Neoadjuvant Chemotherapy in Triple Negative Breast Cancer 94%
Similar papers in this journal
- Segmentation of Pancreatic Ductal Adenocarcinoma (PDAC) and surrounding vessels in CT images using deep convolutional neural networks and Texture Descriptors 94%
- Identifying relationships between imaging phenotypes and lung cancer-related mutation status: EGFR and KRAS 93%
- Improving Rectal Tumor Segmentation with Anomaly Fusion Derived from Anatomical Inpainting: A Multicenter Study 93%
Similar papers in this journal
- PET/CT and SPECT/CT imaging of 90 Y hepatic radioembolization at therapeutic and diagnostic activity levels: anthropomorphic phantom study 94%
- Enhancing Semantic Segmentation in Chest X-Ray Images through Image Preprocessing: ps-KDE for Pixel-wise Substitution by Kernel Density Estimation 94%
- Photon-counting cine-cardiac CT in the mouse 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.