Back

Improved Spectral Inversion of Blood Oxygenation due to Reduced Tissue Scattering: Towards NIR-II Photoacoustic Imaging

Vincely, V. D.; Bayer, C. L.

2024-08-09 bioengineering
10.1101/2024.08.08.607178 bioRxiv
Show abstract

SignificanceConventional spectral photoacoustic imaging (sPAI) to assess tissue oxygenation (sO2) uses optical wavelengths in the first near infrared window (NIR-I). This limits the maximum imaging depth ([~]1 cm) due to high spectral coloring of biological tissues. AimSecond near infrared or short-wave infrared (NIR-II or SWIR) wavelengths (950-1400 nm) show potential for deep tissue sPAI due to the exponentially reduced tissue scattering and higher maximum exposure threshold (MPE) in this wavelength range. However, to date, a systematic assessment of NIR-II wavelengths for sPAI of tissue sO2 has yet to be performed. ApproachThe NIR-II PA spectra of oxygenated and deoxygenated hemoglobin was first characterized using a phantom. Optimal wavelengths to minimize spectral coloring were identified. The resulting NIR-II PA imaging methods were then validated in vivo by measuring renal sO2 in adult female rats. ResultssPAI of whole blood under a phantom and of circulating renal blood in vivo, demonstrated PA spectra proportional to wavelength-dependent optical absorption. NIR-II wavelengths had a [~]50% decrease in error of spectrally unmixed blood sO2 compared to conventional NIR-I wavelengths. In vivo measurements of renal sO2 validated these findings and demonstrated a [~]30% decrease in error of estimated renal sO2 when using NIR-II wavelengths for spectral unmixing in comparison to NIR-I wavelengths. ConclusionssPAI using NIR-II wavelengths improved the accuracy of tissue sO2 measurements. This is likely due to the overall reduced spectral coloring in this wavelength range. Combined with the increased safe skin exposure fluence limits in this wavelength range, demonstrate the potential to use NIR-II wavelengths for quantitative sPAI of sO2 from deep heterogeneous tissues.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

1
Journal of Biomedical Optics
25 papers in training set
Top 0.1%
26.4%
2
Photoacoustics
11 papers in training set
Top 0.1%
12.7%
3
Neurophotonics
37 papers in training set
Top 0.1%
10.7%
4
Biomedical Optics Express
84 papers in training set
Top 0.2%
10.4%
50% of probability mass above
5
Journal of Biophotonics
16 papers in training set
Top 0.1%
7.0%
6
Scientific Reports
3102 papers in training set
Top 26%
4.4%
7
PLOS ONE
4510 papers in training set
Top 44%
2.7%
8
Physics in Medicine & Biology
17 papers in training set
Top 0.2%
2.2%
9
Magnetic Resonance in Medicine
72 papers in training set
Top 0.4%
1.8%
10
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.2%
1.7%
11
Frontiers in Physiology
93 papers in training set
Top 3%
1.5%
12
Annals of Biomedical Engineering
34 papers in training set
Top 0.8%
1.4%
13
Pediatric Research
18 papers in training set
Top 0.2%
1.3%
14
Optics Letters
13 papers in training set
Top 0.2%
1.1%
15
Journal of Visualized Experiments
30 papers in training set
Top 0.7%
0.8%
16
Journal of Neuroscience Methods
106 papers in training set
Top 2%
0.7%
17
ACS Sensors
45 papers in training set
Top 1%
0.7%
18
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 4%
0.5%
19
Journal of Magnetic Resonance Imaging
14 papers in training set
Top 0.7%
0.5%
20
Frontiers in Neurology
91 papers in training set
Top 6%
0.5%
21
Communications Biology
886 papers in training set
Top 31%
0.5%
22
Biology Methods and Protocols
53 papers in training set
Top 3%
0.5%
23
Molecular Metabolism
105 papers in training set
Top 2%
0.5%