Back

Accurate diagnosis achieved via super-resolution whole slide images by pathologists and artificial intelligence

wang, k.; LIU, R.; chen, Y.; wang, y.; qiu, y.; gao, y.; zhou, m.; bai, b.; zhang, m.; sun, k.; Deng, H.-W.; xiao, h.; Yu, G.

2024-07-07 pathology
10.1101/2024.07.05.24310022 medRxiv
Show abstract

BackgroundDigital pathology significantly improves diagnostic efficiency and accuracy; however, pathological tissue sections are scanned at high resolutions (HR), magnified by 40 times (40X) incurring high data volume, leading to storage bottlenecks for processing large numbers of whole slide images (WSIs) for later diagnosis in clinic and hospitals. MethodWe propose to scan at a magnification of 5 times (5X). We developed a novel multi-scale deep learning super-resolution (SR) model that can be used to accurately computes 40X SR WSIs from the 5X WSIs. ResultsThe required storage size for the resultant data volume of 5X WSIs is only one sixty-fourth (less than 2%) of that of 40X WSIs. For comparison, three pathologists used 40X scanned HR and 40X computed SR WSIs from the same 480 histology glass slides spanning 47 diseases (such tumors, inflammation, hyperplasia, abscess, tumor-like lesions) across 12 organ systems. The results are nearly perfectly consistent with each other, with Kappa values (HR and SR WSIs) of 0.988{+/-}0.018, 0.924{+/-}0.059, and 0.966{+/-}0.037, respectively, for the three pathologists. There were no significant differences in diagnoses of three pathologists between the HR and corresponding SR WSIs, with Area under the Curve (AUC): 0.920{+/-}0.164 vs. 0.921{+/-}0.158 (p-value=0.653), 0.931{+/-}0.128 vs. 0.943{+/-}0.121 (p-value=0.736), and 0.946{+/-}0.088 vs. 0.941{+/-}0.098 (p-value=0.198). A previously developed highly accurate colorectal cancer artificial intelligence system (AI) diagnosed 1,821 HR and 1,821 SR WSIs, with AUC values of 0.984{+/-}0.016 vs. 0.984{+/-}0.013 (p-value=0.810), again with nearly perfect matching results. ConclusionsThe pixel numbers of 5X WSIs is only less than 2% of that of 40X WSIs. The 40X computed SR WSIs can achieve accurate diagnosis comparable to 40X scanned HR WSIs, both by pathologists and AI. This study provides a promising solution to overcome a common storage bottleneck in digital pathology.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

1
Journal of Pathology Informatics
15 papers in training set
Top 0.1%
31.8%
2
PLOS ONE
5266 papers in training set
Top 15%
12.7%
3
Diagnostics
50 papers in training set
Top 0.2%
6.9%
50% of probability mass above
4
Scientific Reports
3612 papers in training set
Top 14%
5.7%
5
npj Digital Medicine
118 papers in training set
Top 1%
5.0%
6
Modern Pathology
22 papers in training set
Top 0.1%
4.5%
7
Computers in Biology and Medicine
128 papers in training set
Top 1%
3.5%
8
Frontiers in Medicine
120 papers in training set
Top 2%
2.0%
9
Journal of Medical Imaging
11 papers in training set
Top 0.2%
1.8%
10
PLOS Computational Biology
1863 papers in training set
Top 15%
1.5%
11
Cureus
68 papers in training set
Top 3%
1.4%
12
The American Journal of Pathology
32 papers in training set
Top 0.5%
1.2%
13
Medical Image Analysis
35 papers in training set
Top 0.5%
1.2%
14
IEEE Journal of Biomedical and Health Informatics
37 papers in training set
Top 0.8%
1.2%
15
Biology Methods and Protocols
61 papers in training set
Top 1%
1.2%
16
Animals
23 papers in training set
Top 0.7%
1.0%
17
Advanced Intelligent Systems
11 papers in training set
Top 0.2%
1.0%
18
Cells
249 papers in training set
Top 6%
0.9%
19
BMC Cancer
67 papers in training set
Top 2%
0.9%
20
npj Precision Oncology
53 papers in training set
Top 2%
0.6%
21
Journal of the American Medical Informatics Association
71 papers in training set
Top 2%
0.6%
22
Communications Medicine
113 papers in training set
Top 5%
0.6%
23
Cancers
213 papers in training set
Top 5%
0.6%