Feasibility to virtually generate T2 fat-saturated breast MRI by convolutional neural networks
Liebert, A.; Hadler, D.; Schreiter, H.; Ehring, C.; Brock, L.; Kapsner, L. A.; Eberle, J.; Erber, R.; Emons, J.; Laun, F. B.; Uder, M.; Wenkel, E.; Ohlmeyer, S.; Bickelhaupt, S.
Show abstract
BackgroundBreast magnetic resonance imaging (MRI) protocols often include T2-weighted fat-saturated (T2w-FS) sequences, which are vital for tissue characterization but significantly increase scan time. PurposeThis study aims to evaluate whether a 2D-U-Net neural network can generate virtual T2w-FS images from routine multiparametric breast MRI sequences. Materials and MethodsThis IRB approved, retrospective study included n=914 breast MRI examinations performed between January 2017 and June 2020. The dataset was divided into training (n=665), validation (n=74), and test sets (n=175). The U-Net was trained on T1-weighted (T1w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) sequences to generate virtual T2w-FS images (VirtuT2). Quantitative metrics and a qualitative multi-reader assessment by two radiologists were used to evaluate the VirtuT2 images. ResultsVirtuT2 images demonstrated high structural similarity (SSIM=0.87) and peak signal-to-noise ratio (PSNR=24.90) compared to original T2w-FS images. High level of the frequency error norm (HFNE=0.87) indicates strong blurring presence in the VirtuT2 images, which was also confirmed in qualitative reading. Radiologists correctly identified VirtuT2 images with 92.3% and 94.2% accuracy, respectively. No significant difference in diagnostic image quality (DIQ) was noted for one reader (p=0.21), while the other reported significantly lower DIQ for VirtuT2 (p<=0.001). Moderate inter-reader agreement was observed for edema detection on T2w-FS images (=0.43), decreasing to fair on VirtuT2 images (=0.36). ConclusionThe 2D-U-Net can technically generate virtual T2w-FS images with high similarity to real T2w-FS images, though blurring remains a limitation. Further investigation of other architectures and using larger datasets are needed to improve clinical applicability. Summary StatementVirtual T2-weighted fat-saturated images can be generated from routine breast MRI sequences using convolutional neural networks, showing high structural similarity but with notable blurring, necessitating further refinement for clinical use. Key ResultsO_LIImages with T2w-FS characteristics can be virtually generated from T1w and DWI images using deep learning C_LIO_LIImage blurring occurring in the VirtuT2 image limit clinical use for the current moment C_LIO_LIFurther investigation of different architectures and with larger datasets are necessary in the future to improve the VirtuT2 performance. C_LI
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Improved accuracy of breast volume calculation from 3D surface imaging data using statistical shape models 94%
- Fibre tracing in biomedical images: An objective comparison between seven algorithms 94%
- Enhancing Semantic Segmentation in Chest X-Ray Images through Image Preprocessing: ps-KDE for Pixel-wise Substitution by Kernel Density Estimation 93%
Similar papers in this journal
- Automated cervix biometry, volumetry and normative models for 3D motion-corrected T2-weighted 0.55-3T fetal MRI during 2nd and 3rd trimesters 94%
- Segmentation of Pancreatic Ductal Adenocarcinoma (PDAC) and surrounding vessels in CT images using deep convolutional neural networks and Texture Descriptors 93%
- Developing a Fully Automated Imaging Biomarker for HCC Risk Assessment via MRI-Based Tumor Segmentation and EPM 93%
Similar papers in this journal
- SCU-Net: A deep learning method for segmentation and quantification of breast arterial calcifications on mammograms 95%
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 95%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 93%
Similar papers in this journal
- Pancreas MRI segmentation into head, body, and tail enables regional quantitative analysis of heterogeneous disease 95%
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 95%
- Improved characterization of diffusion in normal and cancerous prostate tissue through optimization of the restriction spectrum imaging signal model 91%
Similar papers in this journal
- Simulated Diagnostic Performance of Ultra-Low-Field MRI: Harnessing Open-Access Datasets to Evaluate Novel Devices 93%
- Frequency and Phase Correction of GABA-Edited Magnetic Resonance Spectroscopy using Complex-Valued Convolutional Neural Networks 93%
- Liver Volumetry from Magnetic Resonance Images with Convolutional Neural Networks 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.