Back

Does the PolyJet Printing Technology Affect Mechanical Properties of 3D Printed Synthetic Tissue?

Kohnle, S.; Bermel, E.; Severseike, L.; Bhatia, V.

2024-06-22 bioengineering
10.1101/2024.06.18.599608 bioRxiv
Show abstract

Within the medical field, there are multiple opportunities in which 3D printed anatomical models could be utilized such as physician training, surgical planning, education, and R&D testing. Because of this, it is vital to choose materials that most closely mechanically mimic the tissues that would be seen within the simulated model. Stratasys currently has a line of Digital Anatomy (DA) printers that contain predetermined compositions and mixtures called anatomical presets to mimic soft tissue materials such as liver, myocardium, aortic, and epicardium tissue. Different compositions of these printed materials have been previously printed on the J750 Digital Anatomy printer and have undergone mechanical testing. Stratasys is releasing a new printer called J5 Digital Anatomy printer that will also have the capabilities of printing anatomical presets. To compare any differences between the two printer sample types, these mechanical tests were repeated on the J5 DA printer. Mechanical testing included stiffness testing of printed liver samples, compliance testing of printed myocardium samples, and lubricity testing of printed cardiac tissue samples. Stiffness of J5 DA liver and J750 DA liver samples were similar with slight variation seen in more rigid J5 DA samples; however, both printer samples still fell within the stiffness range observed in porcine liver tissue. Compliance testing showed comparable stiffness between J5 DA and J750 DA myocardium samples; however, J5 DA samples tended to be slightly less stiff making them more similar to porcine myocardium stiffness. Thinner J5 DA samples were more variable when compared to J750 DA samples; however, this was minimal variability when compared to that experienced in porcine tissue. Lubricity testing showed comparable coefficients of friction between J5 DA and J750 DA samples with the exception of Mineral oil and Dry lubricants. J5 DA cardiac samples saw smaller coefficients of friction; however, these still fell within the range of aortic and epicardium coefficients of frictions. Because of these results, it can be concluded that the J5 DA printer samples are comparable to J750 DA printer samples and are alternatives to animal tissue benchtop testing depending on the application.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

1
PLOS ONE
4510 papers in training set
Top 5%
23.6%
2
Annals of Biomedical Engineering
34 papers in training set
Top 0.1%
20.4%
3
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 0.3%
4.5%
4
Journal of the Mechanical Behavior of Biomedical Materials
22 papers in training set
Top 0.1%
4.2%
50% of probability mass above
5
Bioengineering
24 papers in training set
Top 0.1%
4.1%
6
Acta Biomaterialia
85 papers in training set
Top 0.2%
3.8%
7
Journal of Biomechanics
57 papers in training set
Top 0.2%
3.8%
8
Scientific Reports
3102 papers in training set
Top 48%
2.2%
9
Biofabrication
32 papers in training set
Top 0.4%
2.0%
10
Cytotherapy
14 papers in training set
Top 0.2%
1.8%
11
Cellular and Molecular Bioengineering
21 papers in training set
Top 0.1%
1.7%
12
Journal of Visualized Experiments
30 papers in training set
Top 0.4%
1.3%
13
Journal of Orthopaedic Research
19 papers in training set
Top 0.2%
1.0%
14
HardwareX
16 papers in training set
Top 0.2%
1.0%
15
ACS Omega
90 papers in training set
Top 3%
0.9%
16
Royal Society Open Science
193 papers in training set
Top 4%
0.9%
17
Bioengineering & Translational Medicine
21 papers in training set
Top 0.7%
0.9%
18
Journal of Biomedical Materials Research Part A
18 papers in training set
Top 0.3%
0.8%
19
Translational Vision Science & Technology
35 papers in training set
Top 0.5%
0.8%
20
PeerJ
261 papers in training set
Top 13%
0.8%
21
Journal of Biomechanical Engineering
17 papers in training set
Top 0.3%
0.8%
22
Advanced Materials Technologies
27 papers in training set
Top 0.6%
0.8%
23
Gigabyte
60 papers in training set
Top 1%
0.8%
24
JAMA Network Open
127 papers in training set
Top 5%
0.7%
25
Biomedical Optics Express
84 papers in training set
Top 1%
0.5%
26
Science Advances
1098 papers in training set
Top 34%
0.5%
27
Developmental Biology
134 papers in training set
Top 3%
0.5%
28
Journal of Biomedical Optics
25 papers in training set
Top 0.8%
0.5%
29
Biology Open
130 papers in training set
Top 4%
0.5%
30
Cureus
67 papers in training set
Top 6%
0.5%