Back

Assessing the Stability of Photon-Counting CT: Insights from a Two-Year Longitudinal Study

Liu, L. P.; Pasyar, P.; Liu, F.; Cao, Q.; Sandvold, O. F.; Sahbaee, P.; Shinohara, R. T.; Litt, H. I.; Noël, P. B.

2024-06-05 radiology and imaging
10.1101/2024.06.05.24308046 medRxiv
Show abstract

ObjectiveAmong the advancements in computed tomography (CT) technology, photon-counting computed tomography (PCCT) stands out as a significant innovation, providing superior spectral imaging capabilities while simultaneously reducing radiation exposure. Its long-term stability is important for clinical care, especially longitudinal studies, but is currently unknown. This study sets out to comprehensively analyze the long-term stability of a first-generation clinical PCCT scanner. MethodsOver a two-year period, from November 2021 to November 2023, we conducted weekly identical experiments utilizing the same multi-energy CT protocol. Throughout this period, notable software and hardware modifications were meticulously recorded. Various tissue-mimicking inserts were scanned weekly to rigorously assess the stability of Hounsfield Units (HU) and image noise in Virtual Monochromatic Images (VMIs) and iodine density maps. ResultsSpectral results consistently demonstrated the quantitative stability of PCCT. VMIs exhibited stable HU values, such as variation in relative error for VMI 70 keV measuring 0.11% and 0.30% for single-source and dual-source modes, respectively. Similarly, noise levels remained stable with slight fluctuations linked to software changes for VMI 40 and 70 keV that corresponded to changes of 8 and 1 HU, respectively. Furthermore, iodine density quantification maintained stability and showed significant improvement with software and hardware changes, especially in dual-source mode with nominal errors decreasing from 1.44 to 0.03 mg/mL. Conclusion This study provides the first long-term reproducibility assessment of quantitative PCCT imaging, highlighting its potential for the clinical arena. Key PointsQuestion: Photon-counting CT (PCCT) provides critical spectral imaging for improved diagnostic accuracy, but its long-term quantitative stability over time is still unknown. Findings: The clinical PCCT system demonstrated stable Hounsfield Units (HU) and image noise over two years, ensuring reliable quantitative imaging and improving diagnostic accuracy. Clinical Relevance: This study showcased the exceptional value of PCCT in diagnostic radiology, particularly for its application in longitudinal studies.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

1
Physics in Medicine & Biology
18 papers in training set
Top 0.1%
29.2%
2
Medical Physics
14 papers in training set
Top 0.1%
13.2%
3
Scientific Reports
3612 papers in training set
Top 4%
10.9%
50% of probability mass above
4
PLOS ONE
5266 papers in training set
Top 27%
5.6%
5
Journal of Medical Imaging
11 papers in training set
Top 0.1%
3.3%
6
Magnetic Resonance in Medicine
85 papers in training set
Top 0.3%
2.8%
7
European Radiology
15 papers in training set
Top 0.2%
2.8%
8
Photoacoustics
12 papers in training set
Top 0.1%
2.5%
9
Biomedical Physics & Engineering Express
11 papers in training set
Top 0.1%
2.4%
10
Journal of Biomedical Optics
28 papers in training set
Top 0.2%
2.4%
11
Journal of Magnetic Resonance Imaging
16 papers in training set
Top 0.2%
2.2%
12
European Journal of Nuclear Medicine and Molecular Imaging
20 papers in training set
Top 0.1%
1.8%
13
NMR in Biomedicine
28 papers in training set
Top 0.3%
1.8%
14
Diagnostics
50 papers in training set
Top 1%
1.4%
15
Archives of Clinical and Biomedical Research
28 papers in training set
Top 0.7%
1.2%
16
Biomedical Optics Express
95 papers in training set
Top 0.7%
1.2%
17
Analytical Biochemistry
26 papers in training set
Top 0.3%
1.2%
18
Nature Communications
5641 papers in training set
Top 54%
1.0%
19
NeuroImage
903 papers in training set
Top 6%
0.9%
20
Imaging Neuroscience
282 papers in training set
Top 4%
0.9%
21
International Journal of Radiation Oncology*Biology*Physics
25 papers in training set
Top 0.5%
0.6%
22
BMJ Open
601 papers in training set
Top 13%
0.6%
23
Magnetic Resonance Imaging
23 papers in training set
Top 0.5%
0.6%