On the influence of the vascular architecture on Gradient Echo and Spin Echo BOLD fMRI signals across cortical depth: a simulation approach based on realistic 3D vascular networks
Baez-Yanez, M. G.; Siero, J. C. W.; Curcic, V.; van Osch, M. J. P.; Petridou, N.
Show abstract
GE-BOLD contrast stands out as the predominant technique in functional MRI experiments for its high sensitivity and straightforward implementation. GE-BOLD exhibits rather similar sensitivity to vessels independent of their size at submillimeter resolution studies like those examining cortical columns and laminae. However, the presence of nonspecific macrovascular contributions poses a challenge to accurately isolate neuronal activity. SE-BOLD increases specificity towards small vessels, thereby enhancing its specificity to neuronal activity, due to the effective suppression of extravascular contributions caused by macrovessels with its refocusing pulse. However, even SE-BOLD measurements may not completely remove these macrovascular contributions. By simulating hemodynamic signals across cortical depth, we gain insights into vascular contributions to the laminar BOLD signal. In this study, we employed four realistic 3D vascular models to simulate oxygen saturation states in various vascular compartments, aiming to characterize both intravascular and extravascular contributions to GE and SE signals, and corresponding BOLD signal changes, across cortical depth at 7T. Simulations suggest that SE-BOLD cannot completely reduce the macrovascular contribution near the pial surface. Simulations also show that both the specificity and signal amplitude of BOLD signals at 7T depend on the spatial arrangement of large vessels throughout cortical depth and on the pial surface.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Combined Angiographic, Structural and Perfusion Radial Imaging using Arterial Spin Labeling 97%
- QSM Reconstruction Challenge 2.0: a realistic in silico head phantom for MRI data simulation and evaluation of susceptibility mapping procedures 97%
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging 96%
Similar papers in this journal
- Medullary vein architecture modulates the white matter BOLD cerebrovascular reactivity signal response to CO2: observations from high-resolution T2* weighted imaging at 7T 97%
- Decoding the microstructural properties of white matter using realistic models 97%
- Accuracy and precision in super-resolution MRI: Enabling spherical tensor diffusion encoding at ultra-high b-values and high resolution 96%
Similar papers in this journal
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 96%
- Deep-Learning-Based Accelerated and Noise-Suppressed Estimation (DANSE) of quantitative Gradient Recalled Echo (qGRE) MRI metrics associated with Human Brain Neuronal Structure and Hemodynamic Properties 96%
- MRS-Sim: Open-Source Framework for Simulating Realistic In Vivo-like MR Spectroscopy Data 96%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.