Single-shot water-fat imaging with multi-echo blip-rewound EPI
Wu, W.
Show abstract
PurposeTo develop a method for single-shot water-fat imaging. MethodsSingle-shot blip-rewound EPI (rEPI) is a fast imaging technique that can acquire multiple echo MRI images with a snapshot. Dixons method separates water and fat signals using signals acquired with different echo times. Combining multi-echo rEPI with properly chosen echo times and Dixon-based post-processing generates water and fat images with a single-shot scan. ResultsPhantom and in vivo experiments were performed to evaluate the proposed method. In phantom scans, water and fat signals are robustly separated using the proposed method, and the obtained water signal is much cleaner than that obtained by conventional EPI acquisition with fat suppression. In vivo experiments show that fat suppression can be obtained using the proposed method without fat saturation pulses, reducing SAR and shortening scan time. In addition, fat signal can also be reconstructed based on the proposed method. ConclusionA single-shot water-fat imaging technique has been successfully developed, a significant advancement that offers speed and robustness in separating water and fat signals for human MRI scans.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T 97%
- Robust 3D Bloch-Siegert based B1+ mapping using Multi-Echo General Linear Modelling 96%
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging 96%
Similar papers in this journal
- Deep-Learning-Based Accelerated and Noise-Suppressed Estimation (DANSE) of quantitative Gradient Recalled Echo (qGRE) MRI metrics associated with Human Brain Neuronal Structure and Hemodynamic Properties 95%
- A Phantom System Designed to Assess the Effects of Membrane Lipids on Water Proton Relaxation 94%
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 94%
Similar papers in this journal
Similar papers in this journal
Similar papers in this journal
- Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses 96%
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions 95%
- Slice-direction geometric distortion evaluation and correction with reversed slice-select gradient acquisitions 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.