An aortic hemodynamic fingerprint reduced order modeling analysis reveals traits associated with vascular disease in a medical biobank
Sokolow, R.; Kissas, G.; Beeche, C.; Swago, S.; Thompson, E. W.; Viswanadha, M.; Chirinos, J.; Damrauer, S.; Perdakaris, P.; Rader, D. J.; Witschey, W. R. T.
Show abstract
PurposeTo determine the clinical relevance of reduced order model (ROM) aortic hemodynamic imaging-derived phenotypes (IDPs) for a range of flow conditions applied to computed tomography (CT) scan data in the Penn Medicine Biobank (PMBB). MethodsThe human thoracic aorta was automatically segmented in 3,204 chest CT scans from patients in the Penn Medicine Biobank (PMBB) patients using deep learning. Thoracic aorta anatomic IDPs such as aortic diameter and length were computed. Resistance, and flow boundary conditions, were varied, resulting in 125,000 ROM simulations, producing a fingerprint of aortic hemodynamics IDPs for a range of flow conditions. To determine the clinical relevance of the aortic hemodynamic fingerprint, untargeted phenome wide association studies (PheWAS) for disease conditions were performed using aortic geometries and pulse pressure as IDPs. ResultsBy utilizing patient metadata from the PMBB, the human aortic radius for different age groups over a normalized radius was visualized, showing how the vessel deforms with age, as well as other characteristic geometric information. The average radius of the ascending thoracic aortic data set was 26.6 {+/-} 3.1 mm, with an average length of 310 {+/-} 37 mm. A combination of pathology codes (phecodes) and hemodynamic simulations were utilized to develop a relationship between them, showing a strong relationship between the resulting pulse pressure and diseases relating to aortic aneurysms and heart valve disorders. The average pulse pressure calculated by the model was 22.5 {+/-} 8.5 mmHg, with the maximum pressure modeled by the system being 201 mmHg, with the minimum being 63.6 mmHg. The pulse pressures of the most significant phecodes were examined for patients with and without the condition, showing a slight separation between the two cases. The pulse pressure was also slightly negatively correlated with the calculated tapering angle of the ascending thoracic aorta. ConclusionsROM hemodynamic simulations can be applied to aortic imaging traits from thoracic imaging data in a medical biobank. The derived hemodynamic fingerprint, describing the response of the aorta to a range of flow conditions, shows clinically relevant associations with disease.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm 98%
- Biomechanical stress analysis of Type-A aortic dissection at pre-dissection, post-dissection, and post-repair states 97%
- Hemodynamics Indicates Differences Between Patients With And Without A Stroke Outcome After Left Ventricular Assist Device Implantation 97%
Similar papers in this journal
- A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, Fabrication, and Physiological relevancy 96%
- Development of a Novel Index to Characterise Arterial Dynamics Using Ultrasound Imaging 96%
- Estimating pulse wave velocity from the radial pressure wave using machine learning algorithms 95%
Similar papers in this journal
- Deep learning-based end-to-end automated stenosis classification and localization on catheter coronary angiography 94%
- Mid-term subclinical myocardial injury detection in patients recovered from COVID-19 according pulmonary lesion severity 93%
- Analysis of vascular architecture and parenchymal damage generated by reduced blood perfusion in decellularized porcine kidneys using a gray level co-occurrence matrix 93%
Similar papers in this journal
- Impact of residual intimal flap displacement post-TEVAR on TBAD haemodynamics in compliant, patient-specific CFD simulations informed by MRI 98%
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 97%
- Quantitative Assessment of Aortic Hemodynamics for Varying Left Ventricular Assist Device Outflow Graft Angles and Flow Pulsation 97%
Similar papers in this journal
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part I: Establishing Credibility of an Advanced Model 96%
- Computational hemodynamic indices to identify Transcatheter Aortic Valve Implantation degeneration 95%
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part II: Effects on Leaflet Mechanics, Hemodynamics, and Stent Deflection Contributing to Thrombogenic Risk and Structural Degeneration 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.