Back

Analytical Validation of a Highly Accurate and Reliable Next-Generation Sequencing-Based Urine Assay

Couto-Rodriguez, M.; Danko, D. C.; Wells, H. L.; Rey, S.; Jirau Serrano, X.; Papciak, J.; Combs, P. F.; Fidler, G.; Mason, C. E.; Otto, C.; O'Hara, N. B.; Nagy-Szakal, D.

2024-04-07 infectious diseases
10.1101/2024.04.05.24305286 medRxiv
Show abstract

Culture is currently the gold standard for diagnosis of urinary tract infections (UTIs); however, it has poor sensitivity detecting urogenital pathogens, especially if patients have already initiated antimicrobial therapy, or have an infection from an organism that is not commonly cultured. False negative urine culture results can lead to the inappropriate use of antimicrobial therapies or to the progression to urosepsis in high-risk patients. Though not commonly applied to urine in a clinical setting, Next-generation sequencing (NGS)-based metagenomics offer a solution as a precision diagnostic. We developed and validated BIOTIA-ID, a clinical-grade NGS-based diagnostic pipeline for the detection and identification of pathogens in urine specimens. Remnant clinical urine specimens, and contrived sterile urine spiked with common UTI pathogens, were processed with our end-to-end assay including extraction, metagenomic library preparation and Illumina NextSeq 550 sequencing. We trained and applied a bioinformatic pipeline that uses machine learning (ML) to identify pathogens. Internal controls and other quality control measures were incorporated into the process to provide rigorous and standardized results. The assay was tested on 1,470 urine specimens and achieved 99.92% sensitivity, 99.95% specificity and a limit of detection (LoD) of <25,000 CFU/mL and <5,000 CFU/mL in bacteria and fungi, respectively. Discordant results were reconciled with additional testing by target-specific qPCR or 16S Sanger sequencing; 87% of the NGS results were ultimately determined to be the correct result. Overall, these data demonstrate that BIOTIA-ID is a highly accurate clinical-grade diagnostic tool with notable advantages over current culture- based diagnostics. Conflict of Interest StatementMCR, DCD, HLW, SR, XJS, JP, PFC, GF, CEM, CO, NBO and DNS are employees at Biotia, Inc.

Published in Microbiology Spectrum (predicted rank #2) · training set

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.