At-home validation of remote breathing monitoring: A proof-of-concept for long-term care of respiratory patients using a non-contact, radar-based biomotion sensor
Fischer, T.; Eggert, T.; Wildenauer, A.; Dietz-Terjung, S.; Voisard, R.; Schoebel, C.
Show abstract
PurposeLong-term monitoring of respiratory rate (RR) is promising for the management of chronic conditions. Research interest is particularly high in chronic respiratory diseases (CRDs), especially for predicting acute exacerbations of COPD (AECOPD). The aim of the present study was to evaluate the long-term validity of a recent non-contact biomotion sensor in the home environment of CRD patients with domiciliary ventilator support, focusing on patient acceptance and usability of this device, as well as RR fluctuations related to AECOPD. Patients and methodsIn this prospective proof-of-concept study, 19 patients requiring non-invasive ventilation (NIV) and seven patients requiring invasive mechanical ventilation (IMV) were provided with the non-contact device for six and one month, respectively. Main indication for NIV therapy was COPD. Real-world validation of the device was performed by comparing nocturnal RR values between the non-contact system and both types of ventilators. The acceptance and operability of the biomotion sensor were evaluated using a questionnaire. COPD exacerbations that occurred during the study period were assessed for possible RR fluctuations preceding these events. ResultsMean absolute error (MAE) of median RR between the NIV device and the non-contact system, based on 2326 nights, was 0.78 (SD: 1.96) breaths per minute (brpm). MAE between the IMV device and the non-contact system was 0.12 brpm (SD: 0.52) for 215 nights. The non-contact device was accepted by the patients and proved to be easy to use. In some of the overall 13 cases of AECOPD, RR time courses showed variations of increased nocturnal respiratory activity a few days before the occurrence of such events. ConclusionThe present non-contact system is suitable and well accepted for valid long-term monitoring of nocturnal RR in the patients home environment. This finding may serve as a starting point for larger studies, e.g., to develop robust AECOPD prediction rules. KEY MASSAGES What is already known on this topicTechnological advances offer new possibilities for remote respiratory rate (RR) monitoring for various use cases. Although novel devices are regularly validated in an experimental environment, the often-recommended verification of this validity in long-term use, including an assessment of patient adherence, is lacking. What this study addsOne of the main challenges is the absence of a feasible reference standard for long-term RR measurement. The present work demonstrates a new approach to validate a non-contact device in the home environment by comparing RR measurements with built-in software data in a cohort of ventilator-dependent patients. How this study might affect research, practice or policyPatient compliance, difficulties, as well as their needs and requirements for such long-term monitoring were recorded in order to improve further patient-centered studies. Following this premise, we aim to encourage the development of suitable validation standards, as long-term RR monitoring could finally become viable.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Two-way remote monitoring allows effective and realistic provision of home-NIV to COPD patients with persistent hypercapnia 95%
- Remote-management of COPD: Evaluating Implementation of Digital Innovation to Enable Routine Care (RECEIVER) – Protocol for a feasibility and service adoption observational cohort study 93%
- Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients 93%
Similar papers in this journal
- Performance of EasyBreath ® Decathlon Snorkeling mask for Delivering Continuous Positive Airway Pressure 96%
- A Cross-sectional Feasibility Study to Evaluate the Usability and Efficacy of “Swaasa”: An AI-Platform for Rapid Respiratory Health Assessment 94%
- Kinematic signature of high-risk labored breathing revealed by novel signal analysis 94%
Similar papers in this journal
- Effectiveness of a telenursing intervention program in reducing exacerbations in patients with chronic respiratory failure receiving noninvasive positive pressure ventilation: A randomized controlled trial 94%
- Quantitative detection of sleep apnea with wearable watch device 94%
- Evaluating N95 Respirator Designs: A Mixed-Methods Pilot and Feasibility Study 93%
Similar papers in this journal
- Diagnosing Chronic Obstructive Airway Disease: a diagnostic accuracy study of a smartphone delivered algorithm combining patient-reported symptoms and cough analysis for use in acute care consultations. 94%
- Remote patient monitoring and digital therapeutics in heart failure: lessons from the Continuum pilot study 93%
- The Remote Analysis Of Breath Sound In COVID-19 Patients: A Series Of Clinical Cases 91%
Similar papers in this journal
- HEART rate variability biofeedback for LOng Covid symptoms (HEARTLOC): protocol for a feasibility study 94%
- The Diagnostic Accuracy of Subjective Dyspnea in Detecting Hypoxemia Among Outpatients with COVID-19 93%
- Helmet noninvasive ventilation for COVID-19 patients (Helmet-COVID): study protocol for a multicenter randomized controlled trial 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.