Postmortem MRI of Tissue Frozen at Autopsy
Nair, G.; Sun, R.; Merkel, H.; Hoskin, K.; Bree, K.; Dodd, S.; Koretsky, A.
Show abstract
IntroductionPostmortem MRI provides insight into location of pathology within tissue blocks, enabling efficient targeting of histopathological studies. While postmortem imaging of fixed tissue is gaining popularity, imaging tissue frozen at the time of extraction is significantly more challenging. MethodsTissue integrity was examined using RNA integrity number (RIN), in mouse brains placed between -20 {degrees}C and 20 {degrees}C for up to 24 hours, to determine the highest temperature that could potentially be used for imaging without tissue degeneration. Human tissue frozen at the time of autopsy was sealed in a tissue chamber filled with 2-methylbutane to prevent contamination of the MRI components. The tissue was cooled to a range of temperatures in a 9.4T MRI using a recirculating aqueous ethylene glycol solution. MRI was performed using a magnetization-prepared rapid gradient echo (MPRAGE) sequence with inversion time of 1400 ms to null the signal from 2-methylbutane bath, isotropic resolution between 0.3-0.4 mm, and scan time of about 4 hours was used to study the anatomical details of the tissue block. Results and DiscussionA temperature of -7 {degrees}C was chosen for imaging as it was below the highest temperature that did not show significant RIN deterioration for over 12 hours, at the same time gave robust imaging signal and contrast between brain tissue types. Imaging performed on various human tissue blocks revealed good gray-white matter contrast and revealing subpial, subcortical, and deep white matter lesions typical of multiple sclerosis enabling further spatially targeted studies. ConclusionHere, we describe a new method to image cold tissue, while maintaining tissue integrity and biosafety during scanning. In addition to improving efficiency of downstream processes, imaging tissue at sub-zero temperatures may also improve our understanding of compartment specificity of MRI signal.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Bidirectional crusher gradient method for estimating the labeling efficiency of pseudo-continuous arterial spin labeling MRI in mice 96%
- SNR-Efficient Whole-Brain Pseudo-Continuous Arterial Spin Labeling Perfusion Imaging at 7 Tesla 95%
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging 95%
Similar papers in this journal
Similar papers in this journal
- Non-Invasive Perfusion MR Imaging of the Human Brain via Breath-Holding 95%
- Improved 7 Tesla Transmit Field Homogeneity with Reduced Electromagnetic Power Deposition Using Coupled Tic Tac Toe Antennas 94%
- Transport Pathways and Kinetics of Cerebrospinal Fluid Tracers in Mouse Brain Observed by Dynamic Contrast-Enhanced MRI 94%
Similar papers in this journal
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 95%
- AI-powered Gradient Echo Plural Contrast Imaging (AI-GEPCI): a Comprehensive Multiparametric Neurological Protocol from a Single MRI Scan 92%
- The effect of device configuration and patient body composition on image artifact and RF heating of deep brain stimulation devices during MRI at 1.5T and 3T 92%
Similar papers in this journal
- Increased brain coverage and efficiency when measuring current-induced magnetic fields by use of simultaneous multi-slice echo-planar MRI 94%
- Acceleration of chemical shift encoding-based water fat MRI for liver proton density fat fraction and T2* mapping using compressed sensing 93%
- Dynamic imaging of myelin pathology in physiologically preserved human brain tissue using third harmonic generation microscopy 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.