Pulmonary Ventilation Analysis Using 1H Ultra-Short Echo Time (UTE) Lung MRI: A Reproducibility Study
Tan, F.; Zhu, X.; Chan, M.; Deveshwar, N.; Willmering, M. M.; Lustig, M.; Larson, P. E. Z.
Show abstract
PurposeTo evaluate methods for quantification of pulmonary ventilation with ultrashort echo time (UTE) MRI. MethodsWe performed a reproducibility study, acquiring two free-breathing 1H UTE lung MRIs on the same day for six healthy volunteers. The 1) 3D + t cyclic b-spline and 2) symmetric image normalization (SyN) methods for image registration were applied after respiratory phase-resolved image reconstruction. Ventilation maps were calculated using 1) Jacobian determinant of the deformation fields minus one, termed regional ventilation, and 2) intensity percentage difference between the registered and fixed image, termed specific ventilation. We compared the reproducibility of all four method combinations via statistical analysis. ResultsSplit violin plots and Bland-Altman plots are shown for whole lungs and lung sections. The cyclic b-spline registration and Jacobian determinant regional ventilation quantification provide total ventilation volumes that match the segmentation tidal volume, smooth and uniform ventilation maps. The cyclic b-spline registration and specific ventilation combination yields the smallest standard deviation in the Bland-Altman plot. ConclusionCyclic registration performs better than SyN for respiratory phase-resolved 1H UTE MRI ventilation quantification. Regional ventilation correlates better with segmentation lung volume, while specific ventilation is more reproducible.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Image- vs. histogram-based considerations in semantic segmentation of pulmonary hyperpolarized gas images 96%
- Prospective Motion Correction and Automatic Segmentation of Penetrating Arteries in Phase Contrast MRI at 7 T 95%
- QSM Reconstruction Challenge 2.0: a realistic in silico head phantom for MRI data simulation and evaluation of susceptibility mapping procedures 94%
Similar papers in this journal
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 93%
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 93%
- Magnetic Resonance Spectroscopy Spectral Registration Using Deep Learning 92%
Similar papers in this journal
- Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression 93%
- Deep-Learning-Based Accelerated and Noise-Suppressed Estimation (DANSE) of quantitative Gradient Recalled Echo (qGRE) MRI metrics associated with Human Brain Neuronal Structure and Hemodynamic Properties 93%
- A Phantom System Designed to Assess the Effects of Membrane Lipids on Water Proton Relaxation 93%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.