Electrocardiogram and Photoplethysmogram-based Heart Rate Variability Are Not Equivalent: A Bayesian Simulation Analysis

Dewig, H.; Cohen, J. N.; Renaghan, E. J.; Leary, M. E.; Leary, B. K.; Au, J. S.; Tenan, M. S.

2023-08-24 cardiovascular medicine
10.1101/2023.08.24.23294449 medRxiv
Show abstract

BackgroundHeart rate variability (HRV) is a common measure of autonomic and cardiovascular system function assessed via electrocardiography (ECG). Consumer wearables, commonly employed in epidemiological research, use photoplethysmography (PPG) to report HRV metrics (PRV), although these may not be equivalent. One potential cause of dissociation between HRV and PRV is the variability in pulse transit time (PTT). This study sought to determine if PPG-derived HRV (i.e., PRV) is equivalent to ECG-derived HRV and ascertain if PRV measurement error is sufficient for a biomarker separate from HRV. MethodsThe ECG data from 1,084 subjects were obtained from the PhysioNet Autonomic Aging dataset, and individual PTT variances for both the wrist (n=42) and finger (n=49) were derived from Mol et al. A Bayesian simulation was constructed whereby the individual arrival times of the PPG wave were calculated by placing a Gaussian prior on the individual QRS-wave timings of each ECG series. The standard deviation of the prior corresponds to the PTT variances. This was simulated 10,000 times for each PTT variance. The root mean square of successive differences (RMSSD) and standard deviation of N-N intervals (SDNN) were calculated for both HRV and PRV. The Region of Practical Equivalence bounds (ROPE) were set a priori at {+/-}0.2% of true HRV. The Highest Density Interval (HDI) width, encompassing 95% of the posterior distribution, was calculated for each PTT variance. ResultsThe lowest PTT variance (2.0 SD) corresponded to 88.4% within ROPE for SDNN and 21.4% for RMSSD. As the SD of PTT increases, the equivalence of PRV and HRV decreases for both SDNN and RMSSD. Thus, between PRV and HRV, RMSSD is nearly never equivalent and SDNN is only somewhat equivalent under very strict circumstances. The HDI interval width increases with increasing PTT variance, with the HDI width increasing at a higher rate for RMSSD than SDNN. ConclusionsFor individuals with greater PTT variability, PRV is not a surrogate for HRV. When considering PRV as a unique biometric measure, our findings reveal that SDNN has more favorable measurement properties than RMSSD, though both exhibit a non-uniform measurement error.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
PLOS ONE
5266 papers in training set
Top 10%
18.8%
2
Physiological Measurement
14 papers in training set
Top 0.1%
15.3%
3
Frontiers in Physiology
106 papers in training set
Top 0.2%
6.3%
4
Scientific Reports
3612 papers in training set
Top 15%
5.6%
5
Journal of the American Heart Association
140 papers in training set
Top 2%
4.4%
50% of probability mass above
6
American Journal of Physiology-Heart and Circulatory Physiology
36 papers in training set
Top 0.3%
4.1%
7
Frontiers in Neurology
102 papers in training set
Top 1%
3.2%
8
Physiological Reports
40 papers in training set
Top 0.4%
2.5%
9
Computer Methods and Programs in Biomedicine
28 papers in training set
Top 0.3%
2.4%
10
PLOS Digital Health
106 papers in training set
Top 2%
2.4%
11
Sensors
43 papers in training set
Top 0.6%
1.9%
12
Journal of Applied Physiology
32 papers in training set
Top 0.4%
1.5%
13
Frontiers in Cardiovascular Medicine
53 papers in training set
Top 2%
1.5%
14
The Journals of Gerontology, Series A: Biological Sciences and Medical Sciences
26 papers in training set
Top 0.3%
1.4%
15
IEEE Transactions on Biomedical Engineering
40 papers in training set
Top 0.7%
1.4%
16
Annals of Biomedical Engineering
37 papers in training set
Top 0.7%
1.1%
17
Cureus
68 papers in training set
Top 3%
1.1%
18
iScience
1154 papers in training set
Top 24%
1.1%
19
Journal of Clinical Medicine
97 papers in training set
Top 4%
1.1%
20
Biomedicines
67 papers in training set
Top 2%
1.0%
21
Biology Methods and Protocols
61 papers in training set
Top 2%
1.0%
22
IEEE Access
35 papers in training set
Top 1%
0.9%
23
Journal of Biomechanical Engineering
20 papers in training set
Top 0.6%
0.9%
24
Biomedical Optics Express
95 papers in training set
Top 1.0%
0.9%
25
European Heart Journal - Digital Health
18 papers in training set
Top 0.9%
0.9%
26
Heart Rhythm
23 papers in training set
Top 0.6%
0.9%
27
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.5%
0.6%
28
The American Journal of Cardiology
17 papers in training set
Top 1%
0.6%
29
BMJ Open
601 papers in training set
Top 13%
0.6%
30
Frontiers in Pediatrics
32 papers in training set
Top 1%
0.6%